Használati útmutató Gossen Metrawatt METRAport 3A

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Gossen Metrawatt METRAport 3A (30 oldal) a multiméter kategóriában. Ezt az útmutatót 8 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/30
METRAport3A
Analog Multimeter 3-349-303-15
5/11.11
Operating Instructions
2 GMC-I Messtechnik GmbH
1 Scale
2 Cover of battery compartment
3 Connection socket „10 A“ for the highest current range
4 Connection socket for the measuring range A|
5 Connection socket for the measuring range V (high potential)
6 Connection socket for all measuring ranges
7 Eye for fastening of the carrying strap
8 OFF| ON: on/off switch (off when the instrument is closed)
9 Potentiometer full scale deflection setting for resistance measurement
10 Function switch and range switch
11 Setscrew for mechanical zero
3
4
5
6
1
2
8
10
73
4
5
6
7
9
11
GMC-I Messtechnik GmbH 3
Contents
Page
1 Safety Features and Precautions ............................................................4
2 Application ..............................................................................................6
3 Description .............................................................................................6
4 Operation ................................................................................................7
4.1 Controls ...................................................................................................7
4.2 Starting the Instrument ..............................................................................9
4.3 Voltage Measurement .............................................................................10
4.3.1 DC and AC Voltages up to 600 V (Direct Connection) ................................10
4.4 Current Measurement .............................................................................11
4.4.1 DC and AC Currents up to 1 A (Direct Connection) ....................................12
4.4.2 DC and AC Currents up to 10 A (Direct Connection) ..................................13
4.4.3 DC and AC Currents above 10 A with External Shunt ................................. 13
4.4.4 AC Currents with (Clip-on) Current Transformers ......................................14
4.4.5 DC and AC Currents with (Clip-on) Current Sensors
(Current Transformers with Voltage Output) .............................................15
4.5 Measurement of Composite Voltages and Composite Currents ...................16
4.5.1 Composite Voltages ................................................................................16
4.5.2 Composite Currents ................................................................................16
4.6 Resistance Measurement .......................................................................17
4.7 Test of Diodes and Transistors .................................................................18
5 Technical Data .....................................................................................20
6 Maintenance .........................................................................................24
6.1 Battery ...................................................................................................24
6.2 Melting Fuse ...........................................................................................24
6.3 Housing ..................................................................................................26
7 Recalibration ........................................................................................26
8Accessories .......................................................................................................... 27
8.1 General ..................................................................................................27
8.2 Technical Data for Measurement Cables
(scope of delivery: KS17-2 safety cable set) ..............................................28
9 Repair and Replacement Parts Service
Calibration Center and Rental Instrument Service ...............................29
10 Product Support ....................................................................................29

Termékspecifikációk

Márka: Gossen Metrawatt
Kategória: multiméter
Modell: METRAport 3A

Szüksége van segítségre?

Ha segítségre van szüksége Gossen Metrawatt METRAport 3A, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók multiméter Gossen Metrawatt

Útmutatók multiméter

Legújabb útmutatók multiméter

Uni-T

Uni-T UT33A Útmutató

3 Április 2025
Uni-T

Uni-T UT151A Útmutató

3 Április 2025
Uni-T

Uni-T UT171B Útmutató

3 Április 2025
Uni-T

Uni-T UT139B Útmutató

3 Április 2025
Uni-T

Uni-T UT139A Útmutató

3 Április 2025
Uni-T

Uni-T UT219E Útmutató

3 Április 2025
Uni-T

Uni-T UT89XD Útmutató

3 Április 2025
Proline

Proline 15186 Útmutató

26 Március 2025