Használati útmutató Gigabyte E152-ZE0

Gigabyte szerver E152-ZE0

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Gigabyte E152-ZE0 (138 oldal) a szerver kategóriában. Ezt az útmutatót 7 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/138
E152-ZE0
AMD EPYC™ 7003 UP Server System - 1U Gen4 NVMe
User Manual
Rev. 1.0
Copyright
© 2021 GIGA-BYTE TECHNOLOGY CO., LTD. All rights reserved.
The trademarks mentioned in this manual are legally registered to their respective owners.
Disclaimer
Information in this manual is protected by copyright laws and is the property of GIGABYTE.
Changes to the specications and features in this manual may be made by GIGABYTE without
prior notice. No part of this manual may be reproduced, copied, translated, transmitted, or
published in any form or by any means without GIGABYTE's prior written permission.
Documentation Classications
In order to assist in the use of this product, GIGABYTE provides the following types of documentation:
User Manual: detailed information & steps about the installation, conguration and use of this
product (e.g. motherboard, server barebones), covering hardware and BIOS.
  User Guide: detailed information about the installation & use of an add-on hardware or
software component (e.g. BMC rmware, rail-kit) compatible with this product.
Quick Installation Guide: a short guide with visual diagrams that you can reference easily for
installation purposes of this product (e.g. motherboard, server barebones).
Please see the support section of the online product page to check the current availability of these
documents.
For More Information
For related product specications, the latestrmware and software, and other information please visit our website at
http://www.gigabyte.com
For GIGABYTE distributors and resellers, additional sales & marketing materials are available from our reseller
portal: http://reseller.b2b.gigabyte.com
For further technical assistance, please contact your GIGABYTE representative or visit
https://esupport.gigabyte.com/ to create a new support ticket
For any general sales or marketing enquiries, you may also message GIGABYTE server directly by email:
server.grp@gigabyte.com
Conventions
The following conventions are used in this user's guide:
NOTE!
Gives bits and pieces of additional
information related to the current topic.
CAUTION!
Gives precautionary measures to
avoid possible hardware or software problems.
WARNING!
Alerts you to any damage that might
result from doing or not doing specic actions.
Server Warnings and Cautions
Before installing a server, be sure that you understand the following warnings and cautions.
WARNING!
To reduce the risk of electric shock or damage to the equipment:
Do not disable the power cord grounding plug. The grounding plug is an important safety
feature.
Plug the power cord into a grounded (earthed) electrical outlet that is easily accessible at all
times.
Unplug all the power cords from the power supplies to disconnect power to the equipment.
Shock Hazard! Disconnect all power supply cords before servicing.
Do not route the power cord where it can be walked on or pinched by items placed against it.
Pay particular attention to the plug, electrical outlet, and the point where the cord extends from
the server.
WARNING!
To reduce the risk of personal injury from hot surfaces, allow the drives
and the internal system components to cool before touching them.
WARNING!
This server is equipped with high speed fans. Keep away from hazardous
moving fan blades during servicing.
WARNING!
This equipment is not suitable for use in locations where children are
likely to be present.
WARNING!
This equipment is intended to be used in Restrict Access Location. The
access can only be gained by Skilled person.
Only authorized by well trained professional person can access the
restrict access location.
CAUTION!
Do not operate the server for long periods with the access panel open or removed.
Operating the server in this manner results in improper airow and improper cooling that can
lead to thermal damage.
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the manufacturer.
Dispose of used batteries according to the manufacturer’s instructions.
Electrostatic Discharge (ESD)
CAUTION!
ESD CAN DAMAGE DRIVES, BOARDS, AND OTHER PARTS. WE RECOMMEND THAT YOU
PERFORM ALL PROCEDURES AT AN ESD WORKSTATION. IF ONE IS NOT AVAILABLE,
PROVIDE SOME ESD PROTECTION BY WEARING AN ANTI-STATIC WRIST STRAP AT-
TACHED TO CHASSIS GROUND -- ANY UNPAINTED METAL SURFACE -- ON YOUR SERVER
WHEN HANDLING PARTS.
Always handle boards carefully. They can be extremely sensitive to ESD. Hold boards only by
their edges without any component and pin touching. After removing a board from its protective
wrapper or from the system, place the board component side up on a grounded, static free sur-
face. Use a conductive foam pad if available but not the board wrapper. Do not slide board over
any surface.
System power on/o󰀨: To remove power from system, you must remove the system from
rack. Make sure the system is removed from the rack before opening the chassis, adding, or
removing any non hot-plug components.
Hazardous conditions, devices and cables:
Hazardous electrical conditions may be
present on power, telephone, and communication cables. Turn off the system and discon-nect
the cables attached to the system before servicing it. Otherwise, personal injury or equipment
damage can result.
Electrostatic discharge (ESD) and ESD protection: ESD can damage drives,
boards, and other parts. We recommend that you perform all procedures in this chapter only at
an ESD workstation. If one is not available, provide some ESD protection by wearing an antistatic
wrist strap attached to chassis ground (any unpainted metal surface on the server) when handling
parts.
ESD and handling boards: Always handle boards carefully. They can be extremely
sensi-tive to electrostatic discharge (ESD). Hold boards only by their edges. After removing a
board from its protective wrapper or from the system, place the board component side up on a
grounded, static free surface. Use a conductive foam pad if available but not the board wrapper.
Do not slide board over any surface.
Installing or removing jumpers: A jumper is a small plastic encased conductor that slips
over two jumper pins. Some jumpers have a small tab on top that can be gripped with n-gertips
or with a pair of ne needle nosed pliers. If the jumpers do not have such a tab, take care when
using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with
the pliers, never the wide sides. Gripping the wide sides can dam-age the contacts inside the
jumper, causing intermittent problems with the function con-trolled by that jumper. Take care to
grip with, but not squeeze, the pliers or other tool used to remove a jumper, or the pins on the
board may bend or break.
- 9 -
5-8-2 UEFI Application Boot Priorities 135 .................................................................
5-9 Save & Exit Menu 136 .........................................................................................
5-10 BIOS POST Beep code (AMI standard) 137 .......................................................
5-10-1 PEI Beep Codes 137 ...................................................................................................
5-10-2 DXE Beep Codes 137 .................................................................................................
- 15 - Hardware Installation
1-3 System Block Diagram
mini-DP
PCIe4.0
x
4
PCIe4.0
x
4
M.2
M.2
PCIe4.0
x
8
PCIe4.0
x
16
PCIe4.0
x
16
8 x SATAIII
Riser CMTP182
2 x SlimLine
2 x SlimLine
2-bay 2.5" U.2/SATA
8-Channel DDR4, 8 x DIMMs
Speed up to 3200 MHz
2 x PCIe p15-x16 FHFL slots
(support 1 x DW GPU or 2 x SW GPUs)
1 x PCIe p15-x16 LPHL slot
Riser CRSE020
Riser CRSH01H
PCIe4.0
x
16
PCIe4.0
x
16
1 x PCIe p15-x16 LPHL slot
Riser CRSH01E
PCIe4.0 x16
PCIe2.0 x2
PCIe2.0 x1
USB2.0 x1
OCP 3.0 mezzanine
Switch NCSI
NCSI
NCSI
Intel
i350-AM2
2 Gx 1 LAN
Flash
512 MB
TPM
USB3.0 / USB2.0 x2
2 x USB 3.0
AMD MILAN
“Zen3” Core
Socket SP3
MUX
MLAN
RGMII 10/100/1G
PHY
USB2.0 x1 USB2.0 x1
USB HUB
GL850G
ASPEED
AST2600
BMC
Flash
32 MB

Termékspecifikációk

Márka: Gigabyte
Kategória: szerver
Modell: E152-ZE0

Szüksége van segítségre?

Ha segítségre van szüksége Gigabyte E152-ZE0, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók szerver Gigabyte

Gigabyte

Gigabyte TO24-JD0 Útmutató

16 December 2024
Gigabyte

Gigabyte G292-Z43 Útmutató

11 Október 2024
Gigabyte

Gigabyte MS33-CP0 Útmutató

29 Augusztus 2024
Gigabyte

Gigabyte R133-X11 Útmutató

29 Augusztus 2024
Gigabyte

Gigabyte R183-S97 Útmutató

29 Augusztus 2024
Gigabyte

Gigabyte R113-C10 Útmutató

29 Augusztus 2024
Gigabyte

Gigabyte R183-SF0 Útmutató

29 Augusztus 2024
Gigabyte

Gigabyte R133-X13 Útmutató

29 Augusztus 2024
Gigabyte

Gigabyte R183-S96 Útmutató

29 Augusztus 2024

Útmutatók szerver

Legújabb útmutatók szerver