Használati útmutató Festo NEBM-M23G15-EH-7.5-Q9N-S1LEG21

Festo nincs kategorizálva NEBM-M23G15-EH-7.5-Q9N-S1LEG21

Olvassa el alább 📖 a magyar nyelvű használati útmutatót Festo NEBM-M23G15-EH-7.5-Q9N-S1LEG21 (2 oldal) a nincs kategorizálva kategóriában. Ezt az útmutatót 2 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/2
6.
8.
NEBM-M23G15-...-S1LEG21
Motor cable
Festo SE & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
Assembly instructions
8152341
2023-09
[8152343]
8152341
Translation of the original instructions
© 2023 all rights reserved to Festo SE & Co. KG
1 Applicable documents
All available documents for the product
èwww.festo.com/sp.
2 Safety
2.1 Safety instructions
Before working on the product: Switch off the power supply, ensure that it is off
and secure it against being switched on again.
2.2 Intended use
The motor cable connects the servo motor EMMT-AS to the servo drive CMMP-AS.
2.3 Training of qualified personnel
Work on the product may only be carried out by qualified personnel who can
evaluate the work and detect dangers. The qualified personnel are trained in
electrical engineering.
3 Additional information
Accessories èwww.festo.com/catalogue.
4 Structure
4.1 Product design
1 23
456 7
Fig.1
1
M23x1 socket
2
Sub-D plug
3
Wire end (6x)
4
Cable
5
Shielded connection
6
Line end
7
Screw (2x)
4.2 Contact assignment
Electrical connection1
Field device side
Signal Electrical connection2
Controller side
1Socket 3Wire ends1)
A U BU
B V BN
C W BK
D Not assigned
PE PE GNYE
1 BR- BUWH
2 Not assigned
3 Not assigned
4 BR+ GNWH
1) Colour code in accordance with IEC 60757:2021-06
Tab. 1: Contact assignment for motor and brake
Electrical connection1
Field device side
Signal Electrical connection2
Controller side
1Socket 2Plug connector
5 Up 10
6 0V 3
7 DATA+ 12
8 DATA- 5
9 CLK+ 13
10 CLK- 6
Tab. 2: Encoder contact assignment
5 Assembly
5.1 Mounting electrical connection 1
1. Align the socket to fit the plug.1
2. Connect the socket to the plug and click into position.1
5.2 Electrical connection 1 strain relief
NOTICE
Movements of the cable can cause malfunction and material damage.
Push-in connector on the field device is damaged by transferred application of
force.
Ensure sufficient strain relief at a maximum 30cm away from the socket.
5.3 Mounting electrical connection2
1. Fasten the shield connection to the servo drive with the shield clamp5
èOperating instructions, servo drive.
2. Connect the wire ends in accordance with the contact assignment.3
3. If necessary, lay the line end in a loop and secure with cable binders to6
maintain the required distance from other components.
4. Align the plug to fit the socket.2
5. Insert the plug into the socket.2
6. Tighten the screws . Tightening torque: 0.4Nm±55%7
5.4 Electrical connection 2 strain relief
Fix the cable in the area of the shield connection .5
ÄForce is not transferred to the insulated wires.
5.5 Wiring
Character-
istics
Cable characteristics Wiring
-E Suitability for energy chains In energy chain or flexible
Tab. 3: Wiring
5.6 Mounting in energy chain
1. Lay out the energy chain lengthways.
2. Place the cables in the energy chain without twisting them.
3. Separate cables from each other using separators/drilled holes.
4. Do not bind cables in bundles.
5. Maintain spaceX. X 10%of the cable diameterD.>
With the energy chain hanging vertically: increase the spaceX.
Align the energy chain in the working position:
Make sure that the radius is greater than the bending radiusR of the
cables.
The cables can move freely in the bending radius KR of the energy chain.
ÄThe cable movement is not forced by the energy chain.
7. Mount the energy chain corresponding instruction manual.è
Fasten the cables:
for short energy chains with a length 1m at both ends of the energy<
chain
for long sliding energy chains with a length 1m at the driver end only>
9. Do not move cables all the way to the fastening point.
ÄThe mounting spaceA between the fastening point and bending move-
ment is maintained.
NOTICE
Damage to cables if the chain breaks.
Replace cables after a chain break.
NOTICE
Malfunction and material damage due to vertically suspended cables.
The cables stretch.
Regularly check the length of the cables.
Readjust the cables if required.
6 Technical data
NEBM-M23G15-...-S1LEG21 -Q7 -Q9 -Q10
Certificates, declaration of conformity èwww.festo.com/sp
Cable characteristic Suitability for energy chains
Cable function 3x motor cable
Cable composition [mm²] 4x0.75 + 1x
(2x0.75) + 1x
(2x0.24 + 2x
2x0.15)
4x1.5 + 1x
(2x0.75) + 1x
(2x0.24 + 2x
2x0.15)
4x2.5 + 1x
(2x1.0) + 1x
(2x0.24 + 2x
2x0.15)
Shielding Shielded
Cable diameter D1 [mm] 12 12.8 13.9
Diameter of shield sleeve D2 [mm] approx. 13.2 approx. 14 approx. 15
Mounting space A [mm] 250 250 300³ ³ ³
Current rating at 40°C [A] 11.7 17.8 23.7
Surge resistance [kV] 6
Operating voltage range
AC UB[V] 0…630
DC UB[V] 0…850
Bending radius
Fixed cable installation R [mm] 48 51.2 55.6³ ³ ³
Flexible cable installation R [mm] 90 96 104.3³³³
Ambient temperature
Fixed cable installation [°C] –40…+90
Flexible cable installation [°C] –25…+80
Material
Cable sheath TPE-U(PUR)
Insulating sheath PP
Electrical connection1
Function Field device side
Connection type Hybrid socket
Connection technology M23x1
Type of mounting Snap-locking
Degree of protection In
assembled state
IP67
Electrical connection2
Function Controller side
Connection type Plug connector and Cable
Connection technology Sub-D and open end
Wire ends Wire end sleeve
Degree of protection In
assembled state
IP20
Tab. 4: Technical data

Termékspecifikációk

Márka: Festo
Kategória: nincs kategorizálva
Modell: NEBM-M23G15-EH-7.5-Q9N-S1LEG21

Szüksége van segítségre?

Ha segítségre van szüksége Festo NEBM-M23G15-EH-7.5-Q9N-S1LEG21, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva Festo

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva