Használati útmutató DataVideo TPC-700P

Olvassa el alább 📖 a magyar nyelvű használati útmutatót DataVideo TPC-700P (156 oldal) a nincs kategorizálva kategóriában. Ezt az útmutatót 5 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra

Oldal 1/156
2
Table of Contents
TABLE OF CONTENTS ..................................................................................... 2
WARNINGS AND PRECAUTIONS 6....................................................................
WARRANTY ................................................................................................... 7
S WTANDARD ARRANTY ....................................................................................... 7
T Y WHREE EAR ARRANTY...................................................................................... 8
DISPOSAL 9......................................................................................................
CHAPTER 1 INTRODUCTI ON......................................................................... 10
1.1 F EATURES .................................................................................................. 10
CHAPTER 2 SYSTEM DIAGRAM .................................................................... 11
CHAPTER 3 CONNECTIONS .......................................................................... 12
3 F V .1 RONT IEW .............................................................................................. 12
3.2 R V EAR IEW ................................................................................................ 13
3.3 L V EFT IEW ................................................................................................. 14
3.4 R V IGHT IEW ............................................................................................... 15
CHAPTER 4 HOW TO TURN ON AND TURN OFF THE POWER OF THE TPC-
700/TPC-700P .............................................................................................. 16
CHAPTER 5 TPC-700 & TPC- . 700P’S SETTINGS OPTION ................................ 17
CHAPTER 6 BASIC SETUP ............................................................................. 24
6.1 C S A ONNECT BY TATIC IP DDRESS.................................................................... 24
6.2 C DHCP ONNECT BY ..................................................................................... 24
CHAPTER 7 NETWORK SETTINGS ................................................................. 25
7.1 C S A ONNECT BY TATIC IP DDRESS.................................................................... 25
7.2 C DHCP ONNECT BY ..................................................................................... 30
CHAPTER 8 THE 8 PRE-SAVED VIRTUAL SCENES FOR THE SE-3200 & TPC-
700/TPC-700P COMBINATION ..................................................................... 33
8.1 T I I HE NPUT NTERFACE ETTINGS FOR THE S SE-3200 & TPC-700/TPC-700P
C OMBINATION.................................................................................................. 34
3
8.2 T 8 P - HE RE SAVED VIRTUAL SCENES FOR THE AND SE-3200 TPC-700/TPC-700P
C OMBINATION.................................................................................................. 37
CHAPTER 9. HOW TO SET THE CHROMAKEY, SAVE A STILL TO MEMORY, P- -IN
P AND STILL FUNCTIONS .............................................................................. 40
CHAPTER 10 INTRODUCTION OF THE SE-3200 APP INTERFACE FOR THE TPC-
700/TPC-700P .............................................................................................. 41
10.1 V S IRTUAL CENES .......................................................................................42
10.1.1 H R P - V S OW TO ECALL THE RE SAVED IRTUAL CENES BY THE TPC-700/TPC-700P
.....................................................................................................................46
10.2 AUX ....................................................................................................... 47
10.2.1 H U F OW TO SE THE “AUX” UNCTION ......................................................... 47
10.3 C P ROSS OINT............................................................................................ 49
10.3.1 H U C P F OW TO SE THE ROSS OINT UNCTION ................................................. 49
10.4 F S LEX OURCE............................................................................................ 52
10.4.1 H U F S F OW TO SE THE LEX OURCE UNCTION .................................................53
10.5 PIP......................................................................................................... 55
10.6 S ETUP ..................................................................................................... 57
CHAPTER 11. INTRODUCTION OF THE BUILT-IN VGB-2000 APP INTERFACE
FOR THE TPC-700/TPC-700P ........................................................................ 60
11.1 M I TPC- A -S & D AIN NTERFACE OF THE 700 PP INGLE UAL.................................. 61
11.2 O S PERATION TEPS FOR THE PP FOR VGB-2000 A TPC-700/TPC- 700P ............. 63
CHAPTER 12 INTERFACE INTRODUCTION OF THE TPC-700/TPC-700P BUILT-IN
DVK-400 APP ............................................................................................... 70
12.1 H OME ..................................................................................................... 70
12.2 I NPUT/OUTPUT ........................................................................................72
12.3 C HROMAKEY.............................................................................................73
12.4 L UMAKEY ................................................................................................. 74
12.5 W INDOW ................................................................................................76
12.6 USER MEMORY ..................................................................................... 77
12.7 C ONNECT................................................................................................. 78
12.8 S ETUP ..................................................................................................... 79
CHAPTER 13 INTERFACE INTRODUCTION OF THE TPC-700/TPC-700P BUILT-IN
ZR-1 APP ...................................................................................................... 85
4
13.1 C ONNECTIONS .......................................................................................... 85
13.2 -1 M I ZR AIN NTERFACE ............................................................................... 86
13.2.1 3 cams Interface-Home ................................................................. 88
13.2.2 2 cams Interface-Home ................................................................. 93
13.2.3 Connecon-for 3 cams & 2 cams Interfaces ................................. 95
13.2.4 Encoding-for 3 cams & 2 cams Interfaces ..................................... 97
13.2.5 Camera-for 3 cams & 2 cams Interfaces ..................................... 107
13.2.6 Switcher-for 3 cams & 2 cams Interfaces ...................................109
13.2.7 Audio-for 3 cams & 2 cams Interfaces ........................................ 116
CHAPTER 14 INTERFACE INTRODUCTION OF THE TPC-700/TPC-700P BUILT-IN
TVS-2000A APP .......................................................................................... 118
14.1 H OME ................................................................................................... 118
14.2 A DVANCE...............................................................................................126
14.3 S . TUDIO ................................................................................................ 128
CHAPTER 15 SOFTWARE UPDATE (APP MANAGE SW) . .............................. 130
CHAPTER 16. DIMENSIO NS ........................................................................ 132
CHAPTER 17. SPECIFICATIO NS ................................................................... 133
APPENDIX .................................................................................................. 134
SOFTWARE UPDATE PROCEDURE FOR TPC-700 & TPC-700P ...................... 134
1. INTRODUCTION ................................................................................ 134
2. PREPARATION .................................................................................. 134
2.1 YSTEM EQUIREMENTSS R ....................................................................134
2.2 S U P OFTWARE PDATE REPARATION................................................................ 135
2.3 S C D YSTEM ONNECTION IAGRAM .................................................................. 136
2.4 C S V HECKING THE OFTWARE ERSION .............................................................. 138
2.5 P S REPARING THE OFTWARE ......................................................................... 142
3. UPDATE ................................................................................................. 142
3.1 U S PDATING THE OFTWARE .......................................................................... 142
SERVICE AND SUPPORT ............................................................................. 156
5
Disclaimer of Product & Services
The information oered in this instrucon manual is intended as a guide only. At all mes,
Datavideo Technologies will try to give correct, complete and suitable informaon. However,
Datavideo Technologies cannot exclude that some informaon in this manual, from me to me,
may not be correct or may be incomplete. This manual may contain typing errors, omissions or
incorrect informaon. Datavideo Technologies always recommend that you double check the
informaon in this document for accuracy before making any purchase decision or using the
product. Datavideo Technologies is not responsible for any omissions or errors, or for any
subsequent loss or damage caused by using the informaon contained within this manual. Further
advice on the content of this manual or on the product can be obtained by contacng your local
Datavideo Oce or dealer.
6
FCC Compliance Statement
This device complies with part 15 of the FCC rules. Operaon is subject to the
following two condions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference
that may cause undesired operaon.
Warnings and Precauons
1. Read all of these warnings and save them for later reference.
2. Follow all warnings and instrucons marked on this unit.
3. Unplug this unit from the wall outlet before cleaning. Do not use liquid or
aerosol cleaners. Use a damp cloth for cleaning.
4. Do not use this unit in or near water.
5. Do not place this unit on an unstable cart, stand, or table. The unit may
fall, causing serious damage.
6. Slots and openings on the cabinet top, back, and boom are provided for
venlaon. To ensure safe and reliable operaon of this unit, and to
protect it from overheang, do not block or cover these openings. Do not
place this unit on a bed, sofa, rug, or similar surface, as the venlaon
openings on the boom of the cabinet will be blocked. This unit should
never be placed near or over a heat register or radiator. This unit should
not be placed in a built-in installaon unless proper venlaon is
provided.
7. This product should only be operated from the type of power source
indicated on the marking label of the AC adapter. If you are not sure of
the type of power available, consult your Datavideo dealer or your local
power company.
8. Do not allow anything to rest on the power cord. Do not locate this unit
where the power cord will be walked on, rolled over, or otherwise
stressed.
9. If an extension cord must be used with this unit, make sure that the total
of the ampere rangs on the products plugged into the extension cord do
not exceed the extension cord rang.
10. Make sure that the total amperes of all the units that are plugged into a
single wall outlet do not exceed 15 amperes.
7
11. Never push objects of any kind into this unit through the cabinet
venlaon slots, as they may touch dangerous voltage points or short out
parts that could result in risk of re or electric shock. Never spill liquid of
any kind onto or into this unit.
12. Except as specically explained elsewhere in this manual, do not aempt
to service this product yourself. Opening or removing covers may expose
you to dangerous voltage points or other risks, and will void your
warranty. Refer all service issues to qualied service personnel.
13. Unplug this product from the wall outlet and refer to qualied service
personnel under the following condions:
a. When the power cord is damaged or frayed;
b. When liquid has spilled into the unit;
c. When the product has been exposed to rain or water;
d. When the product does not operate normally under normal
operang condions. Adjust only those controls that are covered by
the operang instrucons in this manual; improper adjustment of
other controls may result in damage to the unit and may oen
require extensive work by a qualied technician to restore the unit to
normal operaon;
e. When the product has been dropped or the cabinet has been
damaged;
f. When the product exhibits a disnct change in performance,
indicang a need for service.
Warranty
Standard Warranty
Datavideo equipment are guaranteed against any manufacturing defects
for one year from the date of purchase.
The original purchase invoice or other documentary evidence should be
supplied at the me of any request for repair under warranty.
The product warranty period beings on the purchase date. If the purchase
date is unknown, the product warranty period begins on the thireth day
aer shipment from a Datavideo oce.
All non-Datavideo manufactured products (product without Datavideo
logo) have only one year warranty from the date of purchase.
8
Damage caused by accident, misuse, unauthorized repairs, sand, grit or
water is not covered under warranty.
Viruses and malware infecons on the computer systems are not covered
under warranty.
Any errors that are caused by unauthorized third-party soware
installaons, which are not required by our computer systems, are not
covered under warranty.
All mail or transportaon costs including insurance are at the expense of
the owner.
All other claims of any nature are not covered.
All accessories including headphones, cables, and baeries are not
covered under warranty.
Warranty only valid in the country or region of purchase.
Your statutory rights are not aected.
Three Year Warranty
All Datavideo products purchased aer July 1st, 2017 are
qualied for a free two years extension to the standard
warranty, providing the product is registered with Datavideo
within 30 days of purchase.
Certain parts with limited lifeme expectancy such as LCD panels, DVD
drives, Hard Drive, Solid State Drive, SD Card, USB Thumb Drive, Lighng,
Camera module, PCIe Card are covered for 1 year.
The three-year warranty must be registered on Datavideo's ocial
website or with your local Datavideo oce or one of its authorized
distributors within 30 days of purchase.
9
Disposal
For EU Customers only - WEEE Marking
This symbol on the product or on its packaging indicates
that this product must not be disposed of with your other
household waste. Instead, it is your responsibility to dispose
of your waste equipment by handing it over to a designated
collecon point for the recycling of waste electrical and
electronic equipment. The separate collecon and recycling of your waste
equipment at the me of disposal will help to conserve natural resources and
ensure that it is recycled in a manner that protects human health and the
environment. For more informaon about where you can drop o your waste
equipment for recycling, please contact your local city oce, your household
waste disposal service or the shop where you purchased the product.
10
Chapter 1 Introducon
Datavide TPC-700/TPC-700P is the best assistant for all 3200 o
switchers, and VGB-2000 presentaon system. The SE-3200 and VGB-
2000 Apps that are installed on the TPC-700/TPC- contain presets 700P
of common operaon funcons. Just tap on the screen to easily select
dierent presets. Each buon can be customized to your liking. Mul-
camera Virtual Studio switching, AUX output, Crosspoint, Flex Source,
and PIP assignment can be done by the TPC-700/TPC-700P. Easy to
transport to your live producon show on the go. Quick connecon.
Simple installaon.
1.1 Features
The Touch Panel supports 800 x 480 resoluon.
Supports Wall mount installaon and complies to standard VESA
dimensions 10cm x 10cm
7” Capacive Touch Panel
Supports PoE Power Supply(For TPC- Only) 700P
11
Chapter 2 System Diagram
12
Chapter 3 Connections
This chapter will show you the connecons of the TPC-700/TPC-700P
Touch Panel Controller. For the details of the TPC- 0/TPC-700P70 ,
please refer to following chapters.
3 Front View .1
Interface
Descripon
Touch Panel
This is the touch panel of the TPC-700/TPC-700P touch
panel controller.
13
3.2 Rear View
Interface
Descripon
Rear Panel
This is the rear panel of the TPC-700/TPC-
700P Touch Panel Controller. It provides
standard VESA 10cm x 10cm mounng holes.
14
3.3 Le View
Interface
Descripon
RJ-45 Ethernet Interface for RS-232 Control only ( )
This RJ-45 interface is for RS-232 Control only. If users
use the TPC-700/TPC-700P to control the SE-3200, it is
no need for this interface to connect due to that the
TPC-700/TPC-700P adopts the DVIP protocol to
control the SE- 0. 320
USB Interface
Users can use this USB interface for updang the
soware and for installing the remote control
soware of other models.
15
3.4 Right View
Interface
Descripon
12VDC IN interface
Please connect a 12V DC power cable to this interface
for powering the TPC-700/TPC-700P .
RJ-45 Ethernet Interface For DVIP Control & PoE
Only
Please connect one end of an RJ-45 Ethernet cable to
this interface and then please connect the other end
of this cable to the device that must be controlled by
the DVIP protocol. This interface can be used for
supporng the PoE (802.3af) Power Supply.
Note: The PoE funcon can be used only for the TPC-
700P.
ON/OFF Power Switch
Users can turn on or turn o the power of the TPC-
700/TPC- by this switch. 700P
16
Chapter 4 How to turn on and turn o the
power of the TPC-700/TPC-700P
How to Turn On the Power
Please use the ON/OFF power switch which is located on the right side
of the TPC-700/TPC-700P to turn on the power of the TPC-700/TPC-
700P.
How to Turn O the Power
Use the ON/OFF switch: Please use the ON/OFF power switch
which is located on the right side of the TPC-700/TPC-700P to
turn o the power of the TPC-700/TPC-700P
Use the APP: There is a Power-O button which is located at the
boom side of the TPC-700 APP. Press this buon can turn o
the power of the TPC-700/TPC-700P.
17
Chapter 5 TPC-700 & TPC- 700P’s Sengs Opon
Aer you turn on the TPC-700 or the TPC-700P, it will enter the main
screen and there is a “Sengs” icon which is located at the top-right
side of the main screen.
Aer pressin -g the icon, you can enter the “TPC 700 Setup” interface, the
purpose for thisTPC 700 Setup page is for you to set various network -
parameters of the TPC-700/TPC-700P. Moreover, it also allows you to install
and uninstall various apps for dierent product models which are installed in
the TPC-700 or the TPC-700P. In the “TPC 700 Setup” interface- , there are
several parameters including “Language”, TPC 700 Network”, App Manage”, -
Autorun last App” and “FW Version”. The main interface of the TPC-700
Setupis shown in the following diagram, please refer to following paragraphs
for details.
18
Language: Please press this buon to select your desired language from
three languages including tradional Chinese, English and simplied
Chinese. After that, please press the “Save” buon for saving the
sengs.
TPC-700 Network: Please press this key to set various network related
parameters including DHCP ON/OFF switch, IP address, Network Mask,
Gateway and Primary DNS. The main interface of the “TPC ork” -700 Netw
opon is shown in the following diagram.
19
DHCP ON/OFF Toggle Switch: If you connect the TPC-700/TPC-700P and
your DVK-400 to the same router and then this ON/OFF toggle switch is
set to “ON”, the TPC-700/TPC-700P will obtain the IP address
automacally from the router. If this ON/OFF toggle switch Is set to
“OFF” and then you need to set the stac IP address and related network
parameters manually by yourself.
IP Address: If the DHCP ON/OFF toggle switch is set to “OFF” and then
you need to set the stac IP address manually from this secon. Aer
the stac IP address is entered, please tap the “OK” buon for applying
it.
Note: Please pay aenon that the stac IP address of the TPC-700/TPC-
700P must be within the same LAN according to the default stac IP
address of the connected Datavideo product.
20
Network Mask: Please press this buon for seng the Network
Mask manually. The default Network Mask is 255.255.255.0
Gateway: Please press this buon for seng the Gateway
address manually. Please refer to user manuals of dierent
product models for seng this value in consistent with the
default value of each product.
21
Primary DNS: Please press this buon for seng the primary DNS
address, the default primary DNS address is 8.8.8.8.
MAC Address: This secon will show the MAC Address of the TPC-
700/TPC-700P.
APP Manage: Press this buon allows you to install related Apps
for the Datavideo products in the TPC-700/TPC-700P. The main
interface of the “App Manage” opon is shown in the following
diagram.
How to uninstall the App
1. Please press the “Uninstall buon beside the product App that is
needed to be uninstalled. Aer that, the App will be uninstalled
automacally.
2. A reminding dialogue box will be shown. Please press the “OK”
buon and then the app will be uninstalled.
How to install App
1. Please download App le for your product model from Datavideo
ocial website hps://www.datavideo.com. The le name is “SE-3200
rmware for TPC-700P_V2.2.10.zip” (Take SE-3200 as an example).
2. Please unzip the downloaded zip le. After that, please unzip the
“product model name_vx.x.x.zip” and then you will see a “datavideo”
le folder with “tpc700.apkg” le in it. Please copy the whole
“datavideo” le folder into the root directory of your USB ash drive.
3. Please insert the USB ash drive into the USB interface which is
located at the le side of the TPC-700/TPC-700P controller.
4. Please press the “Install” buon which is located at the top-right
side of the “App Manage” interface and then the App will be installed
automacally.
Autorun last App ON/OFF toggle switch: If this toggle switch is
“ON”, for the next me when the TPC-700 or the TPC-700P is
turned on, it will run the app which is operated for the last me
automacally.
23
FW Version: This secon will show current version number of the
“App Manage” soware which is installed in the TPC-700 or the
TPC-700P.
LCD Backlight: This slider allows you to adjust the LCD Backlight
brightness with the range of 20%-100%.
24
Chapter 6 Basic Setup
Before using the TPC-700/TPC-700P to control other devices, please
make sure that the basic setup of the TPC-700/TPC-700P is done. This
chapter will make the SE-3200 HD 12-Channel Digital Video Switcher as
an example for explaining how to set the basic setup between the TPC-
700/TPC-700P and the SE-3200. Please set the basic setup of the TPC-
700/TPC-700P according to following steps.
6 Connect by Static IP Address .1
1. Please use an RJ-45 Ethernet cable to connect from the Ethernet
interface on the rear panel of the SE-3200 to the DVIP RJ-45 Ethernet
interface on the right side of the TPC-700/TPC-700P .
6 Connect by DHCP .2
1. Please use an -45 Ethernet cable to connect from the Ethernet RJ
interface on the rear panel of the SE-3200 main unit to the RJ-45
Ethernet interface on your router.
2. Please use an RJ-45 Ethernet cable to connect from the DVIP RJ-45
Ethernet interface on the right side of the TPC-700/TPC- to the RJ-700P
45 Ethernet interface of the same router.
25
Chapter 7 Network Sengs
For the network sengs of the TPC-700/TPC- , please see following 700P
chapters.
7 Connect by Static IP Address .1
If the -700/TPC-700P and the SE-3200 are brand new devices. TPC
The brand new default value of the SE-3200 switcher is the stac IP mode and
the stac IP address is For the brand new TPC-700/TPC-192.168.100.101.
700P Touch Panel Controller, its default network mode is the stac IP address
mode and the IP address is If users want to connect the 192.168.100.102.
TPC-700/TPC-700P to the SE-3200 by the stac IP mode, please connect the
TPC-700/TPC-700P and the SE-3200 with an RJ-45 Ethernet cable.
If the IP address of the -700/TPC-700P or the SE-3200 is not the TPC
default value
If the IP address of the SE-3200 is not the default value, please refer to
Network and Soware Setup for Switcher” in the SE-3200 user manual to
know the IP address, subnet mask and default gateway of the SE-3200. And
then please set the IP address of the TPC-700/TPC-700P to be within the same
IP range for further operaon.
26
Please follow following steps for operaon.
1. Aer the TPC-700 or the TPC-700P is turned on, please tap the “Sengs”
icon.
2. TPC- Please press the “ 700 Network” opon.
27
3. Please turn “ON” the “DHCP ON/OFF” toggle switch. Aer that, you can see
the default stac IP address of the “TPC 700P” is 192.168.100.102. -700/TPC-
The default “Network Mask” is 255.255.255.0. The default “Gateway” address
is 192.168.100.1.
Note: If SE-3200’s IP address is not the default IP address, you need to click
the “IP Address” buon for seng the SE 700P’s IP -3200 and TPC-700/TPC-
addresses within the same LAN by using the keypad which is shown in the
following diagram. Aer that, please click the “OK” buon.
28
4. Aer going back to the “TPC 700 Network” screen, please press the “Apply” -
buon which is located at the top-right side for applying the sengs.
5. Aer going back to the main interface of the TPC-700/TPC-700P, please tap
the SE-3200 App.
29
6. Aer entering the -SE 3200 App, please click the “Setup” and then click the
“Connect”buon.
7. - . Aer that, Please press the “Scan” buon to nd the connected SE 3200
please select the correct SE-3200 IP address from the drop-down menu and
then please press the “Connect” buon for connecng the SE-3200 by the
TPC-700/TPC-700P.
30
7 Connect by DHCP .2
Please follow following steps for connecng the TPC-700/TPC- and the SE-700P
3200 by the DHCP Mode.
1. Aer the TPC-700 or the TPC-700P is turned on, please tap the “ Sengs”
icon.
2. Please tap the - “TPC 700 Network” opon.
31
3. -Please turn “ON” the “DHCP ON/OFF” toggle switch. Aer that, the TPC 700
or the TPC-700P will obtain the network related parameters including IP
address, Network Mask, Gateway AND Primary DNS from the connected
router automacally. Aer all parameters are obtained, please press the
“Apply” buon for applying the sengs.
4. Aer going back to the main interface of the TPC-700/TPC-700P, please tap
the SE-3200 App.
32
5. Aer entering the SE-3200 App, please tap the “Setup” opon and then
click the “Connect” buon.
6 e connected SE-3200. Please select . Please click the “Scan” buon to nd th
the IP address of the connected SE-3200 from the drop-down menu and then
tap the “Connect” buon to connect the TPC-700/TPC-700P to the SE- 3200.
33
Chapter 8 The 8 Pre-saved Virtual Scenes for the SE-
3200 & TPC- 0/TPC- combinaon 70 700P
Datavideo SE-3200 HD 12-Channel Digital Video Switcher allows users
to set up to 4-camera EFP Chromakey eect. So, the SE-3200 & TPC-
700/TPC-700P combinaon allows users to recall the pre-saved 4-
camera EFP Chromakey eect virtual scenes easily and rapidly. The
default seng for the TPC-700/TPC-700P is that the TPC-700/TPC-700P
will recall the No. 101~No. 108 virtual scenes that are pre-saved in the
SE-3200. So, please follow following steps for seng the related “User
Memory” contents. Please see the example which is shown as
following diagram.
34
8 The Input Interface Sengs for the SE-3200 & TPC-.1
700/TPC-700P Combinaon
Before recalling the No. 101 to No. 108 user memories’ virtual scenes,
users need to know the corresponding relaonship between each
interface of the SE-3200 rear panel and the elements for each pre-
saved virtual scene.
Connecons for
the SE-3200 rear
panel
Reminders for Seng up the Cameras
SDI IN 1
( )CH1
Please set the Camera 1 in the middle to shoot the full
body shot for the talent and guests who are sing in front
of the green mat. (Wide Angle).
35
SDI IN 2
( )CH2
Please set the Camera 2 in the middle to shoot the close-
up for the talent and guests who are sing in front of the
green mat.
SDI IN 3
( )CH3
The Camera 3 must be set on the right side to shoot the
close-up for the talent who is sing in front of the green
mat.
36
SDI IN 4
( )CH4
The Camera 4 must be set on the le side to shoot the
close-up for the guests who are sing in front of the
green mat.
CH5
The built-in virtual scene from the SE-3200(Wide Angle virtual
scene)
CH6
The built-in virtual scene from the SE- (The close-up picture 3200
is located in the middle)
CH7
The built-in virtual scene from the SE-3200(The picture is
located at the le side)
CH8
The built-in virtual scene from the SE-3200(The picture is
located at the right side)
37
CH9
Please connect a PC to the HDMI IN9 interface of the SE-
3200(CH9)(for playing slides or videos)
8 The 8 Pre-saved virtual scenes for the SE-3200 and TPC-.2
700/TPC-700P Combinaon
Combinaon of
Screen Elements
Final Composite Screen
Wide Angle with
Background
CH1 Chromakey+CH5
Virtual Scene
Full-Body Chromakey with Virtual Scene
Close-up with
Background CH2
Chromakey+CH6
Virtual Scene
Half-Body Chromakey with Virtual Scene
38
Talent A Close-up
with Background
CH3
Chromakey+CH7
Virtual Scene
Half-Body Talent A Chromakey with Virtual
Scene
Talent B Close-up
with Background
CH4 Chromakey
+CH8 Virtual Scene
Talent B Chromakey with Virtual Scene
Talent A+PC Source
CH3
Chromakey+CH9
Background
Talent A Half-Body + Content
39
Talent B+ PC Source
CH4
Chromakey+CH9
Background
Talent B Half-Body +Content
Talent A Close-up
with Background+ PC
Source) CH3
Chromakey +CH7
Background+CH9
PIP
Talent A Half-Body Chromakey with Virtual
Scene+ Content
Talent B Close-up
with Background +PC
Source CH4
Chromakey+CH8
Background+CH9
PIP
Talent B Half-Body Chromakey with Virtual
Scene+ Content
40
Chapter 9. How to Set the Chromakey, Save a Sll to
Memory, P- -P and Sll Funcons In
It is necessary to use the Chromakey and Sll related funcons of the
SE-3200 for controlling the SE-3200 and for recalling the pre-saved
virtual scenes directly by the TPC-700/TPC-700P. For the seng details
and the operang steps, please refer to the 4.2 Keyer 4.3 Chroma 4.4 , ,
P- -In P and the related paragraphs of the from the SE-Sll 4.9 Files
3200 user manual.
41
Chapter Introduction of t -3200 App Interface 10 he SE
for the TPC-700/TPC-700P
The built-in SE-3200 control App for the Datavideo TPC-700/TPC-700P
includes “Virtual Studio”, “AUX”, “Cross Point”, “Flex Source”, “PIP”
and “Setup” opons for users to control the SE-3200 remotely by the
TPC-700/TPC-700P and an RJ-45 Ethernet cable. The main interface of
the built-in SE-3200 control App for the TPC-700/TPC-700P is shown as
following diagram.
42
10.1 Virtual Scenes
The Virtual Studio opon allows users to recall the pre-saved No. 101
to No. 108 User Mems sengs in the SE-3200 by the TPC-700/TPC-
700P. There are 8 virtual scenes can be used by users including “Wide
Angle with background”, “Close-up with background”, “Talent A close-
up with background”, “Talent B close up with background”, “Talent A + -
PC Source”, “Talent B + PC Source”, “Talent A close-up with
background + PC Source”, “Talent B close-up with background + PC
Source”. The nal eects of those 8 different virtual scenes will be
listed as following diagrams for users’ reference.
1. Wide Angle with background
43
2. Close-up with background
3. Talent A close-up with background
44
4. Talent B close-up with background
5. Talent A + PC Source
45
6 Talent B + PC Source .
7. Talent A close-up with background + PC Source.
46
8. Talent B close-up with background + PC Source.
10.1.1 How to Recall the Pre-saved Virtual Scenes by the TPC-
700/TPC-700P
Please recall the pre-saved virtual scenes by following steps.
1. Please make sure that all of the 8 virtual scenes are saved into the No. 101
to No.108 User Mems in advance. Moreover, please make sure that the SE-
3200 main unit, the control panel, the TPC-700/TPC-700P and the router are
connected correctly.
2. Please tap your desired virtual scene mode directly from the TPC-700/TPC-
700P for recalling the corresponding virtual scene.
47
10.2 AUX
The Datavideo TPC-700/TPC-700P with the SE-3200 control soware allows
users to use the “AUX” funcon. The “AUX” funcon allows users to assign
signal sources including CH1 to CH-12 input sources, PGM, PVW, CLN PGM,
CLN PVW, PG + DSK, MULTIV, MULTIV2, STILL1, STILL2, FLEX SRC and FLEX
SRC2 randomly to the output interfaces such as SDI1, SDI2, SDI3, SDI4, SDI5,
SDI5, SDI6, HDMI1, HDMI2 and HDMI3 to be the output sources. The main
interface of the “AUX” opon is shown as following diagram.
10.2.1 How to Use the AUX” Funcon
Please follow following steps for using the “AUX” funcon.
1. Please select your desired output interface for outpung the signal source
from the “OUTPUT” area.
48
2. Please select your desired signal source for output from the “SELECT” area.
3. Users can nish the signal assigning for the AUX funcon.
1
2
49
10.3 Cross Point
The “Cross Point” opon allows users to adjust the sequence of the input
signals by themselves without changing any input cables. For example, users
can assign the signal source which is originally connected to input 2 to be the
signal source of input 1. Aer the seng is nished, users can see that the
source picture of the input 2 will be shown on the window of input 1. The
main interface of the “Cross Point” is shown as following diagram.
10.3.1 How to Use the Cross Point Funcon
Please follow following steps for using the Cross Point Funcon.
1. Please select the input channel that you want to change the input signal
source from the “INPUT” area.
2. Please select the channel No. that you want to use as the video input signal
sou rce from the “VIDEO XPT” area.
3. Please select the channel No. that you want to use as the audio input signal
source from the “AUDIO XPT” area.
50
NoteIf you want to turn off the area, please tap output of the “VIDEO XPT”
the “OFF” button. If you want to use the embedded audio of the output video
as the output audio source, please tap the “Follow” button.
How to Enter the PGM AUDIO SETTING Interface
1. Please tap the “PGM AUDIO SETTING” button.
2
3
1
51
2. Users can enter the “PGM AUDIO SETTING” interface to adjust the audio
Gain and audio Delay.
How to Use the “PGM AUDIO SETTING” Interface
2
2
1
1
3
3
4
52
1. Please tap the No.1 arrow to decrease the Audio Gain and Audio Delay.
2. Please tap the No. 2 arrow to increase the Audio Gain and Audio Delay.
3. Please tap the No. 3 slider to increase or decrease the Audio Gain and Audio
Delay by dragging the No.3 slider forward or backward.
4. Pl to go ease tap the No. 4 “OK” button to make the setting effective and
back to the previous screen.
10.4 Flex Source
The Flex Source function allows users to show videos in different sources
simultaneously. Those videos can be shown in PROGRAM and PREVIEW
simultaneously and can be set in different permutations.
The Flex Source output consists of a set of background picture and four sets of
smaller source videos which are overlaid on the background picture. Those
four smaller source videos will be displayed by their corresponding sub-picture
windows.
The FLEX1 & FLEX2 buttons within the Flex Source interface allow
users to recall an independent different Bgnd background picture respectively
and four PIP sub-pictures which are shared by the FLEX 1 and FLEX 2 to form a
variety of Flex Source screen combinations. The two Bgnds for the Flex 1 and
Flex 2 are independent respectively. However, all of the four PIP sub-pictures
are shared by the Flex 1 and the Flex 2 and those four PIP sub-pictures are
linked. The main interface of the Flex Source option is shown as following
diagram.
53
10.4.1 How to Use the Flex Source Function
Please follow following steps for using the Flex Source function.
How to Set the Background Picture for the Flex Source
1. At first, please tap the “Src Bgnd” button which is located at the “FLEX 1”
area to select the background function for the Flex Source.
1
2
54
2. Please tap the source signal channel that you want to use to be the Src
background picture e source signal channels from the “SELECT” area. (Th
include BLK, 1~12, STILL 1 & STILL 2, MATTE and BARS).
How to Set the Sub-Picture Source Signal for the P- -P of Flex Source In
1. At first, please tap the “Src 1”, “Src 2”, “Src 3” or “Src 4” button within the
“FLEX 1” area.
2. Please tap the source signal channel that you want to use to be the Src 1,
Src 2, Src 3 or Src 4 sub- signal from the “SELECT” area.
3. Please move the white cross box by your finger to determine the sub-
picture placement for the Src 1, Src 2, Src 3 or Src 4.
4. Please tap the “X”, “Y” or “SIZE” and then those characters will become
orange.
5. Please tap the left or the right arrow button to adjust the scale of the “X”,
“Y” or “SIZE”.
Note: When the X, Y or Size character become orange, users can tap that
character once again and then the character will become light blue. When the
character becomes light blue, users are forbidden to adjust the scale of X, Y or
SIZE.
The ON/OFF button allows users to open or to close the display of the
Flex Source Src1 to Src 4.
How to Use the FLEX 1 & FLEX 2 Buttons
The FLEX 1 & FLEX 2 buttons allow users to recall an independent Bgnd
background pictures for the FLEX 1 and FLEX 2 respectively and four PIP sub-
pictures which are shared by the FLEX 1 and FLEX 2 to form a variety of Flex
Source screen combinations. Please refer to following examples for realizing
the relation between the FLEX 1 & FLEX 2 screen combinations.
Screen
Combination
No.
The Screen for FLEX 1
The Screen for FLEX 2
1
Flex 1 :
Bgnd x 1, PIP x 2
Flex 2 :
Different Bgnd x 1, PIP x 2
55
2
Flex 1 :
Bgnd x 1, PIP x 3
Flex 2 :
Different Bgnd x 1, PIP x 1
3
Flex 1 :
Bgnd x 1, PIP x 4
Flex 2 :
Different Bgnd x 1, PIP x 0
Users can know from the above-mentioned examples that the FLEX 1 mode
and the FLEX 2 mode can display different Bgnd background screen
respectively. However, the four PIP screens must be shared by the FLEX 1 and
FLEX 2 together. It means that if all of the four PIP screens are opened, the
same PIP screens will be shown on both FLEX 1 and FLEX 2.
Note: If users do not want to show the same PIP screens on both FLEX 1 and
FLEX 2, please remember to use the ON/OFF button to hide the
repetitive PIP screens.
10.5 PIP
The main interface of the PIP option allows users to set the PIP related
functions. Please refer to following steps for setting the PIP function.
1
2
3
4
5
56
How to Set the Sub-Picture Source Signal for the PIP
1. At first, please tap the “Src 1”, “Src 2”, “Src 3” or “Src 4” button from the
PIP area.
2. Please tap the source signal channel that you want to use to be the Src 1,
Src 2, Src 3 or Src 4 sub- SOURCE (The source signal signal from the “ ” area.
channels include BLK, 1~12, STILL 1 & STILL FLEX1 & FLEX2, MATTE and 2,
BARS).
3. Please move the white cross box by your finger to determine the sub-
picture placement for the Src 1, Src 2, Src 3 or Src 4.
4. Please tap the “X”, “Y” or “SIZE” and then those characters will become
orange.
5. Please tap the left or the right arrow button to adjust the scale of the “X”,
“Y” or “SIZE”.
Note: When the X, Y or Size character become orange, users can tap that
character once again and then the character will become light blue. When the
character becomes light blue, users are forbidden to adjust the scale of X, Y or
SIZE.
57
10.6 Setup
The built-in SE-3200 control interface of the TPC-700/TPC-700P allows users to
set many parameters including Langua , Connect, Screen Saver, FW Version ge
and Model. The main interface for the Setup is shown as the following
diagram.
1. Language: This button allows users to select three different language
interfaces including Traditional Chinese, English and Simplified Chinese.
Please tap this .Language” button
1
2
3
4
5
6
58
Aer that, users can select their desired language. If the “Save” button
is pressed, it will go back to previous page aer the seng is saved. If
the “Cancel” button is pressed, it will go back to previous page directly.
2. Connect : Press this button for entering the “Connect” interface.
P - lease press the “Scan” button for scanning the connected SE 3200.
Aer the SE- -down menu 3200 is found, Please click the “IP Select” drop
to select the IP address of the connected device.
After that, please click the “Connect” button to connect the TPC-
700/TPC-700P and the SE-3200. If the “Disconnect” button is pressed
during the TPC-700/TPC-700P and the SE-3200 are connected, the
connecon will be cancelled. If the “Cancel” button is pressed, it will go
back to the “Setup” interface.
59
3 Screen Saver. : Please press this buon to enter the “Screen Saver” main
interface which allows you to adjust the screen saver wait me within 0(OFF)
to 10 minutes range by using a slider. Aer the adjustment is nished, please
click the “Save” buon for applying the seng. Once it reaches the preset
me length, the screen saver screen will be shown to save the power
consumpon and to extend the lifeme of the monitor.
60
4. FW Version: This column will show current version number of the SE-3200
App which is installed in the TPC-700/TPC-700P controller.
5. Model: This column will show the product model which is connected by this
App, which is the SE-3200.
6. Quit App: Please press this buon to quit the SE-3200 App
and then go back to the main screen of the TPC-700/TPC-700P.
61
Chapter 11 Introducon of the Built-in VGB-2000 App .
Interface for the TPC-700/TPC-700P
When the User Memory of the SE-1200MU is set, users can use the TPC-700
Touch Panel Controller to apply their needed default mode directly.
11.1 Main Interface of the TPC-700 App-Single & Dual
Please see following diagram for the Single & Dual Camera interface for the
TPC-700 App.
Single Camera
The main interface of the single camera is shown in the following diagram, it
provides dierent mode buons including “Close UP+ Interacve Pen Mark”,
“Close UP+ Interacve Pen Mark+ Logo”, “Interacve Pen Mark + Logo”,
“Interacve Pen Mark” and “Close UP with Chromakey + Sliders”. Moreover,
you can choose Tradional Chinese, Simplied Chinese or English from the
language drop-down menu . Click the buon allows you to quit
the VGB-2000 App and then go back to the main interface of the TPC-
700/TPC-700P.
62
Dual Camera
The main interface of the single camera is shown in the following diagram, it
provides dierent mode buons including “Close UP+ Interacve Pen Mark”,
“Close UP+ Interacve Pen Mark+ Logo”, “Interacve Pen Mark + Logo”,
“Interacve Pen Mark” ”, “Wide Angle with , Close Up with Chromakey
Chromakey” and “Wide Angle with Chromakey + Interacve Pen Mark”.
Moreover, you can choose Tradional Chinese, Simplied Chinese or English
from the language drop-down menu . Click the buon allows
you to quit the VGB-2000 App and then go back to the main interface of the
TPC-700/TPC-700P.
63
11.2 Operaon Steps for the VGB-2000 App for TPC-
700/TPC-700P
The Datavideo TPC-700 Touch Panel Controller allows users to tap the opon
which is shown on the screen for applying the pre-saved eects that are set by
the SE-1200MU. This allows users to use more simple way for applying their
desired eects when shoong the teaching videos. For the operaon of the
TPC-700, please see following steps.
Step 1. At rst, please use a D-Sub 9 pin to RJ-45 adapter cable to connect
from the RS-232 interface which is on the rear panel of the VGB-2000 to the
RJ-45 interface of the TPC-700.
Step 2. Aer the preset sengs of the SE-1200MU are set, users can apply
their desired eects by tapping the opon which is shown on the TPC-700
screen directly.
Single Camera Eects
Close Up+ Interacve Pen Mark
64
Close Up + Interacve Pen Mark + Logo
Interacve Pen Mark + Logo
65
Interacve Pen Mark
Close Up with Chromakey + Slides
66
Dual Camera Eects
Close Up + Interacve Pen Mark
Close Up + Interacve Pen Mark + Logo
67
Interacve Pen Mark + Logo
Interacve Pen Mark
68
Close Up with Chromakey
Wide Angle with Chromakey
69
Wide Angle with Chromakey + Interacve Pen Mark
70
Chapter 12 Interface Introducon of the TPC- /TPC-700
700P Built-in DVK-400 App
The Datavideo TPC-700/TPC-700P built-in DVK-400 app includes “Home”,
“Input/Output”, Chromakey”, “Lumakey” “Window”, “User Memory”,
“Connect” and “Setup” opons for users to control the DVK-400 remotely by
using the TPC- 0/TPC-700P and the RJ-45 Ethernet cable connecon. The 70
main interface of the TPC-700/TPC-700P built-in DVK-400 app is shown in the
following diagram.
12.1 Home
Aer related parameters in the DVK-400 PC App are set in advance, the
“Home” opon provides three buons including “Lumakey ON/OFF, “AUX
Layer Swap Front/Back” and “BG Blur ON/OFF” for you to control the related
funcons.
71
Lumakey ON/OFF Press this buon allows you to switch between the :
“Lumakey ON”and “Lumakey OFF”.
Lumakey ON This allows you to apply the Lumakey eect. :
Lumakey OFF If this buon is pressed, the Lumakey eect will not be :
applied.
AUX Layer Swap Front/Back : Press this buon to switch between “AUX
Layer Swap Front” and “AUX Layer Swap Back”.
AUX Layer Swap Front: If the “AUX Layer Swap Front” is set, the
Chromakey layer will be behind the AUX Lumakey layer.
AUX Layer Swap Back: If the “AUX Layer Swap Back” is set, the
Chromakey layer will be in front of the AUX Lumakey Layer.
BG Blur ON/OFF Press this key : allows you to switch between the “BG
Blur ON” and “BG Blur OFF”.
72
If the “BG Blur ON” is set, it will turn on the BG Blur funcon.
If the “BG Blur OFF” is set, it will turn o the BG Blur funcon.
12.2 Input/Output
Aer related parameters in the DVK-400 PC App are set in advance, the
Input/Output opon allows you to select the foreground input source and the
output or preview screen type. The main interface of the Input/Output opon
is shown in the following diagram.
FG INPUT SOURCE This opon allows you to select the SDI or HDMI :
input to be the foreground input source.
OUTPUT This opon allows you to select dierent signal sources for
the PGM (SDI), PGM (HDMI) and PVW (SDI/HDMI) interfaces .
PGM (SDI): This opon allows you to select the output image type for
the “PGM (SDI) interface.
PGM (HDMI): This opon allows you to select the output image type
for the PGM (HDMI) interface.
PVW (SDI/HDMI): This opon allows you to select the output image
type for the PVW (SDI) (HDMI) interface.
73
The output image sources are shown in the following diagram.
FG: The input source of the foreground camera.
BG: The input source of the background camera.
Mae: Mask.
PFG: Processed Foreground Image.
Comp Composite image for foreground and background images :
Mirror Press this buon can ip the output image to the le side or the :
right side.
Lock Press this buon can lock the output interface and turn o the
image source selecon funcon.
12.3 Chromakey
Aer related parameters in the DVK-400 PC App are set in advance, the
Chromakey opon allows you to turn on or turn o the Chromakey funcon
and to adjust the Black Level and Spill Suppression funcon. The main
interface for the Chromakey funcon is shown in the following diagram.
74
Chromakey ON/OFF Click this toggle switch to turn on or turn o the
Chromakey funcon.
Black Level The Black Level value can be adjusted directly by using this :
slider. The default value of the Black Level is 200. If this value is
increased, black objects or hair will be more obvious. You can adjust the
“Black Level” by using the slider or the le or right arrow buon.
Spill suppression removes the green or blue color reflected onto the
foreground subject from the screen. Setng the spill suppression to zero
removes the green or blue color component and setng the spill suppression
to 500 adds the green or blue color component. A good spill suppression
range is 400 700. The default value is 500. You can use the slider or left and
right arrow keys to adjust the Spill Suppression.
12.4 Lumakey
Aer related parameters in the DVK-400 PC App are set in advance, the
Lumakey opon allows you to turn on or turn o the “Lumakey funcon, to
select the Key mode of the Lumakey and to adjust the “Cut O” level and
“Layer Swap” me. The main interface of the Lumakey opon is shown in the
following diagram.
75
Lumakey ON/OFF toggle switch Click this toggle switch to turn on or
turn o the Lumakey funcon.
KEY MODE There are two Modes including Black and White Modes. :
Click this buon once to switch between the Black and White. Select
“Blackif the foreground is shot against a black background andWhite if
the foreground is shot against a white background.
LAYER SWAP: There are two modes including “Front” and “Back”. Click
this buon once to switch between “Front” and “Back”. Enable “Layer
Swap” to place the Chromakey layer on top of the AUX Lumakey layer
and vice versa.
“Cut O” The default “Cut O” value is 0. Increase this value gradually :
unl either of the black and white backgrounds of the AUX source is
100% removed. For a black background, set Cut O to 10-20% of its
maximum value. For a white background, set Cut O to 80-90% of its
maximum value. You can use the slider or the le and right arrow
buons to adjust the “Cut O” opon.
Swap Time Swap time sets the transion time during layer swap. For :
example, if the swap me is set to 20, mulply this number by 0.1 to
derive the transion me of 2 seconds. You can use the slider or the le
and right arrow buons to adjust the “ ” opon.Swap Time
76
12.5 Window
Aer related parameters in the DVK-400 PC App are set in advance, the
Window opon allows you to turn on or turn o the “Garbage Window and
“Holdout Window” ON/OFF buons. Moreover, it also allows you to adjust the
Top”, “Boom”, ”Le” and “Right range of edges and the values for the so-
edge eect. The main interface of the Window opon is shown in the
following diagram.
77
12.6 USER MEMORY
Aer related parameters in the DVK-400 PC App are set in advance, the User
Memory opon allows you to save or load up to 8 seng values.
How to save the User Memory seng
At rst, please make sure that your desired sengs are set in the
DVK-400 PC App in advance.
Please select one User Memory posion from USER 1 to USER 8 that
you want to save the sengs.
And then please press the “Save” buon for saving the sengs.
How to load the User Memory Sengs:
Please select one User Memory posion that you want to load the
sengs from the USER 1 to USER 8.
And then please press the “Load” buon for loading the sengs.
The main interface of the User Memory is shown in the following diagram.
78
12.7 Connect
After related parameters in the DVK-400 PC App are set in advance, the
“Connect” opon allows you to set “Interface”, “Scan in Network” or “Select
Device” opons. The main interface of the “Connect” opon is shown in the
following diagram.
Interface There are two interfaces including DVIP and RS-232. Please click
the DVIP or the RS-232 button for selecting. Please select the interface
according to the connection interface which is selected in the DVK-400 PC App.
The selection in this section must be the same with the connection interface
which is selected in the DVK-400 PC App.
Scan in Network: If the DVIP interface is selected for connection, press this
button allows you to search the DVK-400 which is connected by the TPC-
700/TPC-700P automatically.
Select Device This option will show the IP address of the connected DVK-400.
Connect When the interface is selected and the DVK-400 is found, please
click this “Connect” buon to connect the TPC-700/TPC-700P with the DVK-
400.
79
12.8 Setup
Aer related parameters in the DVK-400 PC App are set in advance, the
“Setup” opon allows you to set various parameters including “Output
Resoluon”, “HDMI Output Format”, “Language”, “FW Version”, “FPGA
Version”, “Bootloader Version” and “Screen Saver. The main interface of the
“Setup” opon is shown in the following diagram.
80
Output Resoluon Please press this buon to select your desired
output resoluon. Aer that, please press the “Save” buon to select
your desired DVK-400 output resoluon.
HDMI Output Format Please press this buon to select your desired
HDMI output format from e three output formats which are shown in th
the following diagram. Aer the format is selected, please press the
“Save” buon to conrm the selected HDMI output format.
81
Language Please press this buon to select your desired language
from three languages including Tradional Chinese, English and
Simplied Chinese. Aer your desired language is selected, please press
the “Save” buon to conrm the selected language.
FW Version This column will show the soware version of the main
board.
FPGA Version: This column will show the FPGA Version .
Bootloader Version This column will show the Bootloader Version.
Note The FW Version, FPGA Version and Bootloader Version will be shown
only when the TPC-700 or the TPC-700P is connected to the -400 DVK
successfully.
Factory DefaultAer the “Factory Default” buon is pressed, the
Factory Default conrmaon dialogue box will be shown. Aer the
“Reset” buon is pressed, you can reset the DVK-400 App which is
installed in the TPC-700/TPC- to its factory default sengs. 700P
82
83
Quit APPAfter the “Quit APP” button is pressed, the “Quit APP”
dialogue box will be shown. After the “OK” button is pressed, the DVK-
400 App will be closed.
84
Screen Saver: After entering the “Setup” page, please press the “right
arrow” button to show the “Screen Saver” option which is shown in
the following diagram.
After pressing the “Screen Saver” button, you can see the “Screen Saver”
adjustment slider for you to adjust the “Screen Saver” wait time from 0(OFF)
to 10 minutes which is shown in the following diagram. After the adjustment
is finished, please press the “Save” button for applying the setting.
85
Chapter 13 Interface Introduction of the TPC-700/TPC-
700P Built- -1 App in ZR
The Datavideo TPC-700/TPC-700P built-in -1 app is a powerful tool for you ZR
to control the Datavideo iCAST 10 NDI 5-Channel All- -one Streaming in
Switcher web UI functions within one app. Moreover, the ZR-1 app allows you
to control up to 3 cameras at the same time. Before controlling the Datavideo
iCAST 10 NDI, what you need to do is to finish the connections and settings for
all facilities.
13.1 Connections
Before controlling the iCAST 10 NDI by the ZR-1 app, please connect your TPC-
700/TPC-700P to your iCAST 10 NDI according to the following diagram in
advance.
After the connection is done, please make sure that your iCAST 10 NDI, PTZ
cameras and TPC-700 or TPC-700P are set in the same IP range for controlling
your iCAST 10 NDI by the TPC-700 or TPC-700 In the following section, P. we
will introduce the user interface of the ZR-1 app for you.
13.2 ZR-1 Main Interface
After all connections are done, please press the ZR-1 app icon from your TPC-
700 or TPC-700P to enter its main interface. This chapter will take the ZR-1 app
version 1.0.9 as an example. There are two modes in the ZR-1 app user
interface including the “ ” mode and the “ ” mode.3 cams 2 cams Please follow
the steps below to enter the main interface.
1. Please tap the ZR-1 app icon .
2. Please press the “Admin” button. After that, please press the “Apply” button.
3. You will see a keypad, please enter the default administration password.
Default Password: admin
After that, please press the “OK” button to enter the ZR-1 app interface.
87
4. The ZR-1 app will search the connected DVIP devices.
5. After the connected devices are found, the main interface will be shown.
You can tap the button which is located at the top-right side of the screen
to select “2 cams” or “3 cams” main interface.
88
13.2.1 3 cams Interface-Home
1. CAM A The “CAM A” button allows you to show the image source which is
shot by the camera connected to the HDMI input 1 of the iCAST 10 NDI to the
PGM external monitor.
2. CAM B: The “CAM B” button allows you to show the image source which is
shot by the came connected to the HDMI input 2 of the iCAST 10 NDI to the ra
PGM external monitor.
3. CAM C: The “CAM Cbutton allows you to show the image source which is
shot by the camera connected to the HDMI input 3 of the iCAST 10 NDI to the
PGM external monitor.
4. PPT: Press this button to show the PowerPoint image source from the
interactive white board or laptop to the PGM external monitor.
5. Document Camera: Press this button to show the image source of the
document camera to the PGM external monitor.
6. P A: Press this button to show the PowerPoint image source on the PGM IP
external monitor and to show the image source of the camera A in the
inserted sub window.
7. P B:IP Press this button to show the PowerPoint image source on the PGM
external monitor and to show the image source of the document camera in
the inserted sub window.
89
8. Stream: Once the video encoding and streaming related parameters are set
in the “Encoding Encoder and “Encoding Stream” in advance, you can
press this “Stream” button to stream up to 12 video sources including CH1,
CH2, CH3, CH4, CH5 and PGM for the Main and Sub encoders to different live-
streaming platforms simultaneously. If the video streaming is in progress, this
button will be shown in red . If the video is not streamed, this button
will be shown in white
9. Record: Once the video encoding and recording related parameters are set
in the “Encoding Encoder” and “Encoding ฀Record” in advance, you can
press this “ ” button to Record record up to 12 video sources including CH1, CH2,
CH3, CH4, CH5 and PGM for the Main and Sub encoders simultaneously. If the
video recording is in progress, this button will be shown in red . If the
video is not recorded, this button will be shown in white .
10. Volume control slider: This slider allows you to adjust the volume of the
PGM output.
Press the speaker icon to turn on or to mute the PGM volume.
Press the “Volume Lock” between “Lock” and icon to switch
“Unlock”. Once it is locked, the volume can not be adjusted.
11. 2 cams & 3 cams modes switch buttons: Please press this button to
select the “2 cams” mode or the “3 cams” mode . The “4
cams” mode is currently unavailable.
12. Account & Password login button: This button allows you to login into up
to 4 different accounts including 1 administration account and 3 user accounts
by entering “User Name” and “Password” respectively. The example is shown
in the following diagram.
90
Before using this function, you have to make sure that your account and
password are set in advance in “Account & Password Add New User. You can
press the gear icon which is located on the top-right side of the screen to
enter the “settings” page.
13. Gear icon: Please press this gear icon to enter the “Settings” page.
The “Settings” page provides you to set various options including “Language”,
Account & Password”, “Factory Default”, Auto DVIP Scan” and “Screen Saver.
Moreover, it allows you to check the “App Version”. The main interface of the
“Settings” page is shown in the following diagram.
A: Language: Please press this button to select your desired language from
English, Traditional Chinese or Simplified Chinese. After that, please press the
Apply” button. Please note that the “Traditional Chinese” and “Simplified
Chinese” interfaces are currently unavailable.
91
B: Account & Password: Please press this button to change the administration
password, to add a new user, to reset the user password and to delete the
unwanted users. The main interface of the “Account & Password” is shown in
the following diagram.
Change Password: Please press this button to enter the new
administration password by the keypad.
Add New User: Please press “Add New User User Name ” to enter the
user name of a new user account. Please press “Add New User Setting
to enter the password for a new user account. After the new user name
and password are entered, please press the “OK” button and then press
the “Apply” button.
Reset User Password: This button allows you to reset the user password.
Please press this button. Please press the account name which the
password should be changed and then press the “Apply” button. After
that, you can see a reminder, please press “Reset. And then please
enter your new password and press the “OK” button.
Delete User: This button allows you to delete a current user. Please press
92
this button and then press the user name which should be deleted. After
that, please press the “Apply” button. You will see a reminder, please
press the “Delete” button to delete the selected user.
C: Factory Default: This button allows you to reset the app to its factory default
value. Please press this button and then you can see a reminder. After that,
please press the “Yes” button to reset it.
D: Auto DVIP Scan: Please press this button to turn on or turn off the Auto
DVIP Scan function.
E: Screen Saver: This button allows you to set the wait time for activating the
screen saver. Please press this button to adjust the wait time for activating the
screen saver by a slider. The adjusting range is 0-100 min. After the adjustment
is done, please press the “Apply” button to apply it.
F: App Version: This option allows you to see the current ZR-1 app version.
G: Quit App: Please press this button to quit the ZR-1 app.
14. AI Auto-Tracking On/Off buttons for CAM A/CAM B/CAM C/CAM D: Those
four buttons are used to turn on or turn off the AI Auto-
93
Tracking function when Datavideo AI Auto Tracking cameras are connected to
the iCAST 10 NDI. You can connect up to 4 Datavideo AI Auto Tracking cameras
to the HDMI input interfaces on the rear panel of the iCAST 10 NDI. Once the
ZR-1 app detects that the connected cameras are not AI-enabled, those four
buttons will be shown in white. If the ZR-1 app detects that the connected
cameras are AI-enabled cameras, those four buttons will be shown in blue. At
this time, you can press the CAM A, CAM B, CAM C or CAM D button to turn
on the AI Auto-Tracking function. Once the AI Auto-Tracking function is turned
on, those four buttons will be shown in red.
13.2.2 2 cams Interface-Home
1. Teacher Full: Press the Teacher Full to show the half-body image of button
the teacher which is shot by the camera connected to the HDMI input 1 of the
iCAST 10 NDI to the PGM external monitor.
2. Teacher + Wide Angle: Press the Teacher + Wide Angle” button to show
the full-body image of the teacher and the panoramic view of the classroom
which is shot by the camera connected to the HDMI input 2 of the iCAST 10
NDI to the PGM external monitor.
3. PPT: The PPT button of the “2 cams” mode is the same as the PPT button in
. Please refer to in 3 cams mode 4. PPT 13.2.1 3 cams Interface-Home for
details.
4. Document Camera: The Document Ca 2 camsmera button of the mode is
the same as the Document Camera button in 3 cams mode Please refer to .
94
“5. Document Camera” in 13.2.1 3 cams Interface-Home for details.
5. P A The PIP A 2 cams de is the same as the PIP IP : button of the mo A
button in “3 cams mode. Please refer to A “6. PIP in 13.2.1 3 cams Interface-
Home for details.
6. P B The PIP B IP : button of the mode is the same as the PIP 2 cams B
button in “3 cams mode . Please refer to 7. PIP B in 13.2.1 3 cams Interface-
Home.
7. Stream: 2 cams The Stream button of the “ ” mode is the same as the Stream
button in 3 cams mode. Please refer to 8 in . Stream” 13.2.1 3 cams
Interface-Home for details.
8. Record: The Record button of the mode is the same as the 2 cams Record
button in . Please refer to 3 cams mode 9 Record. in 13.2.1 3 cams
Interface-Home for details.
9. Volume control slider : The Volume control slider of the mode is 2 cams
the same as the volume control slider in . Please refer to “103 cams mode .
Volume control slider” in 13.2.1 3 cams Interface-Home for details.
10. 2 cams & 3 cams modes switch buttons: The 2 cams & 3 cams modes
switch buttons 2 cams are the same as the 2 cams & 3 cams of the mode
modes switch buttons 3 cams mode 2 cams & 3 cams in “ . Please refer to “11.
modes switch buttons for details. ” in 13.2.1 3 cams Interface-Home
11. Account & Password login button The Account & Password login button of :
the mode is the same as the 2 cams Account & Password login button in “3
cams mode . Please refer to “12. Account & Password login button” in 13.2.1 3
cams Interface-Home for details.
12. Gear icon: 2 cams as the Gear The Gear icon of the mode is the same
icon in “ . Please refer to “133 cams mode . Gear icon” in 13.2.1 3 cams
Interface-Home for details.
13. AI Auto-Tracking On/Off buttons for CAM A/CAM B/CAM C/CAM D The
Auto-Tracking On/O buons of the 2 cams mode are the same as the “ ”
Auto-Tracking On/Obuons of the 3 cams mode Please refer to “14. AI
Auto-Tracking On/Off buons for CAM A/CAM B/CAM C/CAM D in 13.2.1 3
cams Interface-Home for details.
13.2.3 Connection-for 3 cams 2 cams Interfaces &
The “Connecon” interface allows you to see up to 6 connected devices
including the iCAST 10 NDI. Moreover, the “Connecon” interface also allows
you to set the networking related sengs, to save the current status of the
connected devices and to load the previous saved connected devices. The
“Connecon” interface is shown in the following diagram.
1 Connect: This opon allows you to see the current connected status of your .
devices. If this icon is shown in green, it means that the device is connected
successfully.
2. Model Name: This opon will show the model name of the connected
devices.
3. Name: This opon will show the name of the connected devices. You can
tap the selected device Name” buon to modify the device name for a
specic device.
96
4. Network: This opon allows you to see the IP address of the connected
devices. You can also press the “Network” buon of each connected device to
modify the network sengs.
5. Add Device: If the connected devices can not be found by the automac
scanning, please press Add Device Scan in Network” to add your device
automacally or press Add Device Add Manually to add your device
manually.
6. Delete: This button allows you to delete the current connected device list
which is shown on the screen. Please press “Delete Delete
to delete the unwanted device.
7. Load: This buon allows you to load the pre-saved device list.
When the device list is saved in advance, you can press this buon to load it.
97
8. Save: This buon allows you to save a device list for further use.
When all devices are connected and shown successfully, press this buon to
save the device list.
9. The le and right arrow buons: These two buttons allow you to
switch between the rst and the second pages of the device list.
13.2.4 Encoding-for 3 cams & 2 cams Interfaces
The “Encoding” interface provides three opons including “Encoder, “Record”
and “Stream” for you to set encoding, recording and streaming related setngs.
The main interface of the “Encoding” is shown in the following diagram. Please
press the “Encoder” buon to enter the “Encoder” interface.
The main interface for the “Mainand “Sub” Encoders for the CH1, CH2, CH3,
CH4, CH5 and PGM are the same. We will take the main encoder’s CH1 as an
example.
Encoder
98
You can tap each option including “Resoluon”, Prole”, “Entropy,
Video(bps)”, “Frame Rate” and Level to set your desired value. Aer that,
please press the “Save” buon in each page. Aer all of the parameters are set,
please press the Applybuon. Press the “Reset” buon to reset it to factory
default value.
1. Resolution: This option allows you to set your desired resolution for the
main encoder or sub encoder.
2 Profile: This option allows you to set your desired . “Prole” including
“Baseline”, “High” and “ ” proles. Main
99
.
3. Entropy: You can select “CAVLC” or “CABAC” from the “Entropy” page which
is shown in the following diagram.
4. Video (bps): This opon allows you to select your desired video Bitrate.
100
5. Frame Rate: This opon allows you to select your desired frame rate for the
main or sub encoder.
6. Level: The Level” opon is xed at “High 4.2” and can not be adjusted by
users.
7. “Record” icon: You can press this to switch to the “Recorder” page icon
of the “Encoding” opon.
8. “Stream” icon: You can press this icon Streamto switch to the page
of the “Encoding” opon.
9. GOP: This opon allows you to select your desired “GOP” value.
10. Audio Bitrate: This opon allows you to set your desired audio bitrate.
101
Record
1. Encoder Source: This opon allows you to select “Main Encoder or “Sub
Encoder as the encoder source. Moreover, this opon can be disabled.
102
2. File Name: This opon allows you to set the le name of the recorded le.
Please enter your desired le name and then press the “OK” buon.
3. Type: This opon allows you to set the le type for the recorded le.
4. Recording Time: This opon allows you to set the recording me for the
recorded le.
103
5. Storage Capacity: This opon allows you to set the “Format Type” of the
storage media. Moreover, this opon allows you to see the “Device Name”,
Available Capacity” and “Used Capacity”.
6 Encoder : You can press icon to . icon & “Stream” icon the Encoder
switch to the page. You can press the Stream”Encoder icon to switch
to the “Stream” page.
104
Stream
1. Encoder Source: This opon allows you to set the encoder source for
streaming.
105
2. Stream Type: This opon provides you many stream types including RTSP,
RTMP, TS, HLS, NDI and SRT for you to select.
3. RTSP Port: The default port number is 554 or you can tap this opon to
modify the port number.
4. RTSP HTTP Port: The default port number is 8554 or you can tap this opon
to modify the port number.

Termékspecifikációk

Márka: DataVideo
Kategória: nincs kategorizálva
Modell: TPC-700P

Szüksége van segítségre?

Ha segítségre van szüksége DataVideo TPC-700P, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva DataVideo

DataVideo

DataVideo TTL-100 Útmutató

31 December 2025
DataVideo

DataVideo TLM-170PR Útmutató

30 Szeptember 2024
DataVideo

DataVideo DDC-2512 Útmutató

23 Szeptember 2024
DataVideo

DataVideo RP-54 Útmutató

19 Szeptember 2024
DataVideo

DataVideo VGB-2000 Útmutató

10 Szeptember 2024
DataVideo

DataVideo MS-4000 Útmutató

2 Szeptember 2024
DataVideo

DataVideo ZEK-2 Útmutató

1 Szeptember 2024
DataVideo

DataVideo TVS-1000A Útmutató

1 Szeptember 2024
DataVideo

DataVideo DAC-9P 4K Útmutató

1 Szeptember 2024

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva