Használati útmutató Chauvin Arnoux C.A 5275
Chauvin Arnoux
multiméter
C.A 5275
Olvassa el alább 📖 a magyar nyelvű használati útmutatót Chauvin Arnoux C.A 5275 (86 oldal) a multiméter kategóriában. Ezt az útmutatót 6 ember találta hasznosnak és 2 felhasználó értékelte átlagosan 4.5 csillagra
Oldal 1/86

AC+DC TRMS MULTIMETER C.A 5275
ENGLISH User’s manual

2
PRECAUTIONS FOR USE
This instrument is compliant with the NF EN 61010-1 + NF EN 61010-2-030 safety standard for 1000 V voltages in category
III or 600 V in category IV at an altitude below 2000 m, indoors, and with a maximum pollution level of 2.
Failure to comply with safety instructions can create a risk of electric shock, fire, explosion and destruction of the instrument
or the installations.
Do not use the instrument in an explosive atmosphere or in the presence of inflammable gas or smoke.
Do not use the instrument on networks with a rated voltage or category higher than those mentioned.
Respect the maximum rated voltages and currents between terminals and in relation to the earth.
Do not use the instrument if it seems damaged, incomplete or incorrectly closed.
Before each use, check the condition of the cable insulation, the unit and the accessories. All elements on which
the insulation is damaged (even partially) must be put out of service for repair or disposed of as waste.
Use cables and accessories for voltages according to IEC 61010-031 and measurement categories at least equal to
those of the instrument.
Respect the environmental conditions of use.
Strictly comply with the fuse specifications. Disconnect all cables before opening the fuse access cover.
Do not modify the instrument and do not replace components using equivalent parts. Repairs and adjustments must be
carried out by qualified, approved personnel.
Replace the battery as soon as the symbol appears on the display. Disconnect all cables before opening the
battery access cover.
Use personal protection equipment when conditions require it.
Do not place your hands close to instrument terminals that are in use.
When handling sensors or test probes, do not place fingers beyond the physical finger guard.
MEASUREMENT CATEGORIES
CAT II: Test and measurement circuits directly connected to points of use (power outlets and other similar points) on the
low-voltage network.
E.g. Measurements on circuits in network for household appliances, portable tools and other similar instruments.
CAT III: Test and measurement circuits connected to parts of the building's low-voltage network installation.
E.g. Measurements on distribution switchboards (including secondary meters), the circuit breakers, cabling including cables,
busbars, junction boxes, circuit breakers, power outlets in the fixed installation and industrial instruments and other
equipment such as motors permanently connected to the fixed installation
CAT IV: Test and measurement circuits connected to the source of the building's low-voltage network installation.
E.g. Measurement on equipment installed upstream of the main fuse or building installation cut-off switch .
You have just purchased a C.A 5275 multimeter and we thank you for your confidence in our products.
To obtain the best service from your instrument:
Read these instructions carefully;
Respect the precautions for use.
Meanings of the symbols used on the instrument.
Danger hazard:
The operator undertakes to consult these instructions each time this danger hazard symbol is encountered.
Fuse
9V Battery
The CE marking certifies compliance with European directives.
Double or strengthened insulation
Waste sorting for the recycling of electric and electronic waste in the European Union
AC - Alternating current
AC and DC - Alternating and direct current
Earth
Risk of electric shock

3
CONTENTS
1. OVERVIEW ......................................................................................................................................................... 4
1.1 The display ............................................................................................................................................ 4
1.2. The keys ................................................................................................................................................ 6
1.3. The switch .............................................................................................................................................. 6
1.4. The terminals ......................................................................................................................................... 7
2. Use ...................................................................................................................................................................... 7
2.1 First use ................................................................................................................................................. 7
2.2 Starting up the multimeter ..................................................................................................................... 7
2.3 Turning off the multimeter ...................................................................................................................... 7
2.4 The stand ............................................................................................................................................... 7
3. Functions ............................................................................................................................................................ 8
3.1 Switch functions ..................................................................................................................................... 8
3.2 Key functions ....................................................................................................................................... 14
4. Specifications .................................................................................................................................................. 19
4.1 Reference conditions ........................................................................................................................... 19
4.2 Specifications of the reference conditions ........................................................................................... 19
4.3 Operating conditions ............................................................................................................................ 26
4.4 Construction specifications .................................................................................................................. 26
4.5 Power supply ....................................................................................................................................... 26
4.6 Compliance with international standards ............................................................................................. 27
4.7 Variations in the field of use ................................................................................................................ 28
5. Maintenance ..................................................................................................................................................... 29
5.1 Cleaning ............................................................................................................................................... 29
5.2 Replacing the battery ........................................................................................................................... 29
5.3 Replacing the fuses ............................................................................................................................. 29
5.4 Metrology verification ........................................................................................................................... 29
5.5 Repair .................................................................................................................................................. 29
6. Warranty ........................................................................................................................................................... 30
7. To order ............................................................................................................................................................ 30
Termékspecifikációk
Márka: | Chauvin Arnoux |
Kategória: | multiméter |
Modell: | C.A 5275 |
Szüksége van segítségre?
Ha segítségre van szüksége Chauvin Arnoux C.A 5275, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek
Útmutatók multiméter Chauvin Arnoux

26 Augusztus 2024

26 Augusztus 2024

26 Augusztus 2024

26 Augusztus 2024

26 Augusztus 2024

26 Augusztus 2024

26 Augusztus 2024

26 Augusztus 2024

19 Augusztus 2024

17 Augusztus 2024
Útmutatók multiméter
- multiméter PeakTech
- multiméter Milwaukee
- multiméter Parkside
- multiméter Maxwell
- multiméter Emos
- multiméter Voltcraft
- multiméter Vimar
- multiméter Digitus
- multiméter GW Instek
- multiméter Owon
- multiméter Aim TTi
- multiméter Gossen Metrawatt
- multiméter Amiko
- multiméter Klein Tools
- multiméter Workzone
- multiméter Beha-Amprobe
- multiméter Qian
- multiméter Joy-It
- multiméter Extech
- multiméter Gembird
- multiméter Testo
- multiméter Powerfix
- multiméter Biltema
- multiméter BaseTech
- multiméter REV
- multiméter BENNING
- multiméter Alecto
- multiméter Yato
- multiméter Velleman
- multiméter TFA
- multiméter Monacor
- multiméter Elro
- multiméter Fluke
- multiméter Uni-T
- multiméter Metrix
- multiméter Abus
- multiméter Megger
- multiméter Testboy
- multiméter Sonel
- multiméter Wiha
- multiméter Schneider
- multiméter Kyoritsu
- multiméter Brandson
- multiméter Stanley
- multiméter Silverline
- multiméter Rigol
- multiméter Projecta
- multiméter Multimetrix
- multiméter Weidmüller
- multiméter Laserliner
- multiméter Appa
- multiméter Amprobe
- multiméter Brennenstuhl
- multiméter Ferm
- multiméter Tacklife
- multiméter Somogyi
- multiméter Profile
- multiméter Steren
- multiméter Perel
- multiméter Flir
- multiméter Proline
- multiméter Hager
- multiméter Topcraft
- multiméter Clas Ohlson
- multiméter Plieger
- multiméter Jung
- multiméter Etekcity
- multiméter Cablexpert
- multiméter Greenlee
- multiméter Högert
- multiméter Wago
- multiméter Bruder Mannesmann
- multiméter Keithley
- multiméter Metrel
- multiméter Digi-tool
- multiméter Skandia
- multiméter Elma
- multiméter Hubinont
- multiméter Kewtech
- multiméter Strex
- multiméter Mastech
- multiméter MBS
- multiméter MGL Avionics
- multiméter PCE Instruments
- multiméter Micronta
- multiméter CEM
- multiméter Horex
- multiméter Cosinus
- multiméter Kurth Electronic
- multiméter Testec
- multiméter IWH
- multiméter Weltron
- multiméter Sanwa
- multiméter Rohde & Schwarz
- multiméter EEVBlog
- multiméter Kingcraft
- multiméter HT Instruments
- multiméter Caltek
- multiméter Elworks
- multiméter Bearware
- multiméter Noyafa
Legújabb útmutatók multiméter

3 Április 2025

3 Április 2025

3 Április 2025

3 Április 2025

3 Április 2025

3 Április 2025

3 Április 2025

28 Március 2025

26 Március 2025

14 Január 2025