Oldal 1/16
A版: 英/法/西/葡/意/波/匈 S-S-001204
Filter Pump
Model: #58122
Model: #58123
Hmax 1.0m Hmin 0.19m IPX5
OWNER’S MANUAL
www.bestway-service.com
A
B
B
A
Water flow
Water level
>1/2 inches
Water flow
P6112
P6029
P6029
Inlet
Outlet
Connection Valve
Inside wall
Pool
2m (For France only)
WARNING
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
WARNING TO REDUCE THE RISK OF INJURY, do not permit children to
use this product unless they are closely supervised at all times.
WARNING RISK OF ELECTRIC SHOCK – The pump must be supplied by
an isolating transformer or supplied through a residual current device(RCD)
having a rated residual operating current not exceeding 30mA.
WARNING RISK OF ELECTRIC SHOCK – The pump must be supplied by
an isolating transformer or supplied through a circuit of alternative residual
power (DDR) 30mA maximum. (For France Only)
WARNING RISK OF ELECTRIC SHOCK – The pump cannot be using
while people are inside the pool. Forbid the access of the pool in case of
damage of the filter pump.
DO NOT BURY CORD. Locate cord to minimize abuse from lawn mowers,
hedge trimmers, and other equipment.
WARNING If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order to
avoid a hazard.
WARNING – To reduce the risk of electric shock, do not use extension cord to
connect unit to electric supply; Provide a properly located outlet.
CAUTION – This pump is for use with storable pools only. Do not use with
permanently-installed pools. A storable pool is constructed so that it is capable
of being readily disassembled for storage and reassembled to its original
integrity. A permanently-installed pool is constructed in or on the ground or in
a building such that it cannot be readily disassembled for storage.
IMPORTANT Using the pump with an unmatched electrical supply is
dangerous and will result in catastrophic failure of pump.
RISK OF ELECTRICAL SHOCK – When working with electricity, turn the
electrical power off at the circuit breaker and lock breaker door. Failure to do
so will result in increased risk of shock, injury and possibly death.
DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN
ANY WAY. DO NOT USE ADAPTOR PLUGS. Consult a qualified electrician
for any questions related to the validity of your plugs grounding.
Handle the pump with care. Do not pull or carry the pump by the power cord.
Never pull a plug from the outlet by yanking the power cord. Keep cord free
from abrasions. Sharp objects, oil, moving parts, and heat should never be
exposed to the filter pump.
WARNING – This appliance is not intended for use by persons (Including
children) with reduced physical, sensor or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their
safety. Children should be supervised to ensure that they do not play with the
appliance.
NOTE: Please examine equipment before use. Notify Bestway at the
customer service address listed on this manual for any manufacturing defect
or missing parts at the time of purchase. Verify that the equipment
components represent the filter pump model that you had intended to
purchase.
NOTE: Place pump on a solid and level ground. Please ensure the filter pump
is at least one meter away from the pool. Pay attention to position of pool and
pump so adequate ventilation, drainage, and access for cleaning is available.
Never place pump in an area that may accumulate water, or in an area where
foot traffic will flow around the pool.
Please ensure the filter pump is at least 2 meters away from the pool side.
(For France only)
It is necessary to have the plug accessible after installation of the pool.
The plug of pump shall be at least 3,50m away from the pool. (For France
only)
Electric installations should fulfill the requirements of standards NFC 15-100.
(For France only)
NOTE: Atmospheric conditions may affect the performance and life span of
your filter pump. Take precautions to protect filter pump from unnecessary
wear and tear that may occur during periods of cold, heat and exposure to
sun.
It is imperative to change as soon as possible all the deteriorated parts. Only
use the parts approved by the manufacturer.
NOTE: Do not run the pump more than 15 hours per day.
When chemical products are used to clean the pool water, it is recommended
to respect a minimum filtration time to preserve the health of swimmers which
depends on compliance of health regulation.
NOTE: Do not add chemicals in the filter pump.
NOTE: This product is not intended for commercial use.
SAVE THESE INSTRUCTIONS.
Pump Installation Directions
PART I
Internal Filter Pump Inspection
1) Remove the Filter Cap by unscrewing the Filter Cap Retainer.
2) Inspect the Filter Cartridge ensuring it is centered in the Filter Pump.
3) After inspection, check that the Filter Cap Seal is in place, replace the Filter
Cap and screw the Filter Cap Retainer into position.
Part II
Attach the Hoses to the Filter Pump and the Pool
1) Connect the two Hoses to the pool’s Inlet and Outlet Connection Valves by
screwing the threaded locking rings into position.
NOTE: Install the Connection Valves following the Connection Valve
installation directions.
2) Attach the Hoses to the Filter Pump by screwing the threaded locking rings
into position; ensure the corresponding letters on both the pool and the
Filter Pump match (A to A, B to B).
NOTE: After pump is attached to pool, refer to pool manual for filling
instructions.
NOTE: It is imperative to check that the hydraulic connectors are not
obturated.
Pedestal Fixing
EN60335-2-41 TEST standard requires the filter pump must be vertically fixed
on ground or a certain pedestal made of wood or concrete before use. There
should be two holes 9mm in diameter on the pedestal, the space between
which should be 163mm. Put filter pump on the pedestal and fix them together
by fasten the bolts and nuts. All the pedestal parts should weigh over 18kgs at
least to prevent the pump from accidental falling.
390
163
390
250
163
2-M8 bolt
2-M8 nut
PART III
Preparing the System for Use
1) Open/unscrew the Air Purge Valve on the top of the Filter Pump; air is
released as water fills the Filter Pump.
2) When water comes out of the Air Purge Valve screw it closed and wipe
away any water.
3) To start the Filter Pump, Insert the plug of the filter pump to a residual
current device (RCD).
To start the Filter Pump, Insert the plug of the filter pump to a circuit of
alternative residual power (DDR)-For France Only.
NOTE: To prevent the risk of electrical shock, ensure your hands are
completely dry when plugging-in the Filter Pump.
NOTE: To prevent the risk of electrical shock, never run the Filter Pump when
people are swimming in the pool.
IMPORTANT: DO NOT DRY RUN THE FILTER PUMP Make sure both the
pool’s Inlet and Outlet valves are fully covered by water before operating the
Filter Pump.
Pump Installation Diagram
PUMP MAINTENANCE
CAUTION: YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED
BEFORE ANY MAINTENANCE BEGINS OR SEVERE RISK OF INJURY OR
DEATH EXISTS.
Take action to avoid using pools if the filter has problem.
Check the suction if there is any blocking.
Replace all the damaged components.
Part I
Stop Water Flowing to the Filter Pump
1) Unplug the Filter Pump.
2) Close the Connection Valves.
Part II
Cleaning/Replacing the Filter Cartridge
Do not use product during filter cartridge maintenance.
Illustration (not to scale) of pool and filter-pump
2
S-S-001204
PUMP DISPOSAL
Meaning of crossed -out wheeled dustbin:
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities.
Contact your local government for information regarding the collection
systems available.
If electrical appliances are disposed of in landfills or dumps, hazardous
substances can leak into the groundwater and get into the food chain,
damaging your health and well-being.
When replacing old appliances with new ones, the retailer is legally
obligated to take back your old appliance for disposals at least free of
charge.
PUMP STORAGE
CAUTION: YOU MUST ENSURE THE FILTER PUMP IS UNPLUGGED
BEFORE ANY MAINTENANCE BEGINS OR SEVERE RISK OF INJURY
OR DEATH EXISTS.
1) Unplug the Filter Pump.
2) Follow the instructions as previously outline to stop water flowing to the
Filter Pump and to remove the Filter Cartridge.
3) Discard the Filter Cartridge.
4) Detach all Hoses.
5) Dry all components thoroughly.
6) Store the filter pump in a dry location out of child’s reach.
7) Drain the pool according to the Pool Owner’s Manual.
NOTE: We recommend the use of a wet dry vacuum to dry all components.
NOTE: Coating the Filter Cap Seal with petroleum jelly will greatly enhance
its life span.
PUMP WARRANTY
For information concerning pump warranty please visit our website
at: www.bestway-service.com
Check filter cartridge regularly.
1) Unscrew the Filter Cap Retainer and remove the Filter Cap.
2) Clean the Filter Cartridge with a garden hose.
NOTE: If filter cartridge remains soiled or discolored, replacement is
necessary.
IMPORTANT: For sanitary reasons we suggest replacing the Filter
Cartridge every two weeks.
3) Insert the cleaned Filter Cartridge; ensure it is centered in the Filter
Pump.
4) Check that the Filter Cap Seal is in place.
5) Replace the Filter Cap and screw the Filter Cap Retainer into position.
6) Open the Connection Valves.
7) Open the Air Purge Valve to remove any air from the system as outlined
in Pump Installation Directions PART III: Preparing the System for Use.
To order spare parts of the filter pump, please provide us with part no.
and part name.
P6112
P6113
P6115
P6H115
P6117
P6119
58012(III)
NAME
Air purge valve
Purge valve seal
Filter cap retainer (blue)
Filter cap retainer (grey)
Filter cap
Filter cap seal
Filter cartridge
Hose
Hose (For France)
Hose Seal Ring
P6112
P6113
P6115
P6H115
P6117
P6119
58012(III)
P6517
P6518
P6029
No.
P6029
A
B
Water Outlet
P6517
(For France Only)
P6518
Infall
Information required
Name:
Address:
Zipcode:
City:
Country:
Telephone:
Mobile:
E-MAIL:
Fax:
Limited BESTWAY
® Manufacturer’s Warranty
The product you have purchased comes accompanied a limited warranty.
Bestway®
stands behind our quality guarantee and assures, through a
replacement warranty, your product will be free from manufacturer’s defects
that result in leaks.
To enact a claim, this warranty card must be filled out completely and
returned along with:
1. Your purchase receipt
2. Tear out the label on your pump, and copy them to your purchase receipt
3. Filter cap retainer to be sent by post to the address of the after - sales
centre contacted, for details please refer to your country according to the
information you find on the back cover.
Bestway®
is not responsible for economic loss due to water or chemical
costs. With the exception of replacement product, the results of leak are not
Bestway®
responsibility. Bestway® will not place any products deemed to
have been neglected or having been used outside of the owner’s manual
guidelines.
All the information given need to be complete in order to receive our
assistance.
You have to send also a copy of your purchase receipt together with
this fax.
YOU CAN ALSO VISIT OUR WEB SITE: www.bestway-service.com
For request of spare parts consumer has to send us also the page of the
manual with a cross near the missing or faulty part.
FAX/E-MAIL/TEL: Please refer to your country according to the information
you find on the back cover
Please provide your address details in full. Note: Incomplete address
details will result in delayed shipments.
Ensure there is clear path, free of objects and debris for the area outlined in
the chart below.
WARRANTY 2012
TO: BESTWAY®
SERVICE DEPARTMENT
Water leaking
Others, please describe
Stopped working
Description of problem
Item is incomplete, Which part is missing - Please put the code you
find on the instruction manual
Flow rate
330GAL
530GAL, 800GAL,
1300GAL,1500GAL
2100GAL,
2500GAL
P6114
P6115
P6023
P6H114
P6H115
P6H023
Part No.
(Blue)
Part No.
(Grey)
Figure of filter
cap retainer
DATE
Customer Code Number
330GAL
58145
58145GB
58145GS
530GAL
58148
58148GB
58149
58148GS
800GAL
58117
58117GB
58118
58117GS
58122
58122GB
58123
58122GS
58221
58221GB
58229
1300GAL/1500GAL 2100GAL/2500GAL
3
S-S-001204

Termékspecifikációk

Márka: Bestway
Kategória: nincs kategorizálva
Modell: 58389

Szüksége van segítségre?

Ha segítségre van szüksége Bestway 58389, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók nincs kategorizálva Bestway

Bestway

Bestway 21096 Útmutató

3 Október 2024
Bestway

Bestway 36022 Útmutató

22 Szeptember 2024
Bestway

Bestway 36024 Útmutató

17 Szeptember 2024
Bestway

Bestway 21051 Útmutató

17 Szeptember 2024
Bestway

Bestway 52262 Útmutató

15 Szeptember 2024

Útmutatók nincs kategorizálva

Legújabb útmutatók nincs kategorizálva