User Manual
10M-8505543200-4921-01
EN - IT - FR
Split Type Air Conditioner
BEHPH 090/BEHPH 091
BEHPH 120/BEHPH 121
BEHPH 180/BEHPH 181
BEHPH 240/BEHPH 241
BEVPI 090/BEVPI 091
BEVPI 120/BEVPI 121
BEVPI 180/BEVPI 181
BEVPI 240/BEVPI 241
ENGLISH 3-56
ITALIANO 57-114
FRANÇAIS 115-172
CONTENTS
V2110002
AB UM
Please read this user manual first!
Dear Customer,
Thank you for preferring a Beko product. We hope that you get the best results from your product which
has been manufactured with high quality and state-of-the-art technology. Therefore, please read this entire
user manual and all other accompanying documents carefully before using the product and keep it as a
reference for future use. If you handover the product to someone else, give the user manual as well. Follow
all warnings and information in the user manual.
Meanings of the symbols
Following symbols are used in the various section of this manual:
This product has been manufactured at modern facilities respectful to the environment without harming nature.
Complies with the WEEE Regulation. Does not contain PCB.
C
Important information or useful hints
about usage.
A
Warning for hazardous situations with
regard to life and property.
Warning to actions that must never
perform.
B
Warning for electric shock.
This symbol shows that information is
available such as the operating manual
or installation manual.
Do not cover it.
This symbol shows that the operation
manual should be read carefully.
This symbol shows that a service
personnel should be handling this
equipment with reference to the
installation manual.
(For R32/R290 gas type)
This symbol shows that
this appliance used a
flammable refrigerant.
If the refrigerant is
leaked and exposed
to an external ignition
source, there is a risk
of fire.
16 / 172 EN Split Type Air Conditioner / User Manual
(E)
Display window
In Fan mode, the unit will display the room temperature.
Display Code
Meanings
Front Panel Power Cable (Some Units)
Louver
Functional Filter
(On Back of Main Filter - Some Units)
Remote Control
Remote Control
Holder (Some Units)
Display window
Display window
The unit has a build-in light sensor to
detect the ambient brightness. When the
light is turned off, the display will be off
after 7 seconds, saving energy and offering
you a comfortable sleep.
Displays temperature, operation feature and Error codes:
for 3 seconds when:
TIMER ON is set (if the unit is OFF, remains on when TIMER ON is set)
FRESH, SWING, TURBO, or SILENCE features is turned on
for 3 seconds when:
TIMER OFF is set
FRESH, SWING, TURBO, or SILENCE features is turned off
when defrosting (for cooling & heating units)
when unit is self-cleaning (some units)
when 8°C (46°F) or 12°C (54°F) heating mode is turned on (some units)
when fresh feature is turned on (some units)
when ECO feature is activated (some units)
when wireless control feature is activated (some units)
In Fan mode, the unit will display the room temperature.
In other modes, the unit will display your temperature setting.
Press the LED button on the remote control will turn off the display screen, press the
LED button again during 15 seconds will display the room temperature, if press it
again after 15 seconds, it will turn on the display screen.
3.2 Operating temperature
When your air conditioner is used outside of
the following temperature ranges, certain safety
protection features may activate and cause the
unit to disable.
3 Unit specifications and features
26 / 172 EN Split Type Air Conditioner / User Manual
4. Power voltage should be within 90-110% of
rated voltage. Insufficient power supply can
cause malfunction, electrical shock, or fire.
5. If connecting power to fixed wiring, a surge
protector and main power switch should be
installed.
6. If connecting power to fixed wiring, a switch
or circuit breaker that disconnects all poles
and has a contact separation of at least 1/8in
(3mm) must be incorporated in the fixed wiring.
The qualified technician must use an approved
circuit breaker or switch.
7. Only connect the unit to an individual branch
circuit outlet. Do not connect another appliance
to that outlet.
8. Make sure to properly ground the air conditioner.
9. Every wire must be firmly connected. Loose
wiring can cause the terminal to overheat,
resulting in product malfunction and possible
fire.
10. Do not let wires touch or rest against refrigerant
tubing, the compressor, or any moving parts
within the unit.
11. If the unit has an auxiliary electric heater, it
must be installed at least 1 meter (40in) away
from any combustible materials.
12. To avoid getting an electric shock, never touch
the electrical components soon after the power
supply has been turned off. After turning off
the power, always wait 10 minutes or more
before you touch the electrical components.
AWARNING! Before performing
any electrical Or wiring work, turn
off the Main power to the system.
Step 6: Connect signal and power cables
The signal cable enables communication between
the indoor and outdoor units. You must first
choose the right cable size before preparing it for
connection.
Cable Types
Indoor Power Cable (if applicable): H05VV-F or
H05V2V2-F
Outdoor Power Cable: H07RN-F or H05RN-F
Signal Cable: H07RN-F
CIn North America, choose the
cable type according to the local
electrical codes and regulations.
Minimum Cross-Sectional Area of Power and
Signal Cables (For reference) (Not applicable for
North America)
Rated Current of
Appliance (A)
Nominal Cross-
Sectional Area
(mm²)
> 3 and ≤ 6 0.75
> 6 and ≤ 10 1
> 10 and ≤ 16 1.5
> 16 and ≤ 25 2.5
> 25 and ≤ 32 4
> 32 and ≤ 40 6
The size of the power supply cable, signal cable,
fuse, and switch needed is determined by the
maximum current of the unit. The maximum
current is indicated on the nameplate located on
the side panel of the unit. Refer to this nameplate
to choose the right cable, fuse, or switch.
4 Installation
29 / 172 EN
Split Type Air Conditioner / User Manual
7. Using even pressure, push down on the bottom
half of the unit. Keep pushing down until the
unit snaps onto the hooks along the bottom of
the mounting plate.
C
Keep in mind that the hooks on
the mounting plate are smaller
than the holes on the back of
the unit. If you find that you don’t
have ample room to connect
embedded pipes to the indoor
unit, the unit can be adjusted
left or right by about 30-50 mm
(1.18-1.95in), depending on the
model.
Move to left or right
Move to left or right
30-50mm
(1.18-1.96in)
30-50mm
(1.18-1.96in)
4.3 Outdoor Unit Installation
Install the unit by following local codes and
regulations, there may be differ slightly between
different regions.
60cm (24in)
200cm (79in)
fr m
30cm (12in)
on left
30cm (12in)
from back wall
200cm (79in)
in fornt
60cm (24in)
on right
60cm (24in) above
4.3.1 Installation Instructions – Outdoor
unit
Step 1: Select installation location
Before installing the outdoor unit, you must
choose an appropriate location. The following are
standards that will help you choose an appropriate
location for the unit.
Proper installation locations meet the
following standards:
Meets all spatial requirements shown in
Installation Space Requirements above.
Good air circulation and ventilation
Firm and solid—the location can support the
unit and will not vibrate
Noise from the unit will not disturb others
Protected from prolonged periods of direct
sunlight or rain
Where snowfall is anticipated, raise the unit
above the base pad to prevent ice buildup and
coil damage. Mount the unit high enough to be
above the average accumulated area snowfall.
The minimum height must be 18 inches.
DO NOT install unit in the following locations:
Near an obstacle that will block air inlets and
outlets
Near a public street, crowded areas, or where
noise from the unit will disturb others
Near animals or plants that will be harmed by
hot air discharge
Near any source of combustible gas
In a location that is exposed to large amounts
of dust.
In a location exposed to a excessive amounts
of salty air.
4 Installation
35 / 172 EN
Split Type Air Conditioner / User Manual
5 Refrigerant piping connection
When connecting refrigerant piping, do not let
substances or gases other than the specified
refrigerant enter the unit. The presence of other
gases or substances will lower the unit’s capacity,
and can cause abnormally high pressure in the
refrigeration cycle. This can cause explosion and
injury.
C
The length of refrigerant piping
will affect the performance and
energy efficiency of the unit.
Nominal efficiency is tested
on units with a pipe length
of 5 meters (16.5ft) (In North
America, the standard pipe
length is 7.5m (25’). A minimum
pipe run of 3 metres is required
to minimise vibration & excessive
noise. In special tropical area,
for the R290 refrigerant models,
no refrigerant can be added
and the maximum length of
refrigerant pipe should not
exceed 10 meters (32.8ft).
Refer to the table below for specifications on the
maximum length and drop height of piping.
Maximum Length and Drop Height of Refrigerant
Piping per Unit Model
Model Capacity (BTU/h) Max. Length (m) Max. Drop Height (m)
R410A,R32 Inverter Split
Air Conditioner
< 15,000 25 (82ft) 10 (33ft)
≥ 15,000 and < 24,000 30 (98.5ft) 20 (66ft)
≥ 24,000 and < 36,000 50 (164ft) 25 (82ft)
R22 Fixed-speed Split Air
Conditioner
< 18,000 10 (33ft) 5 (16ft)
≥ 18,000 and < 21,000 15 (49ft) 8 (26ft)
≥ 21,000 and < 35,000 20 (66ft) 10 (33ft)
R410A, R32 Fixed-speed
Split Air Conditioner
< 18,000 20 (66ft) 8 (26ft)
≥ 18,000 and < 36,000 25 (82ft) 10 (33ft)

Termékspecifikációk

Márka: Beko
Kategória: légkondicionáló
Modell: BEVPI 120

Szüksége van segítségre?

Ha segítségre van szüksége Beko BEVPI 120, tegyen fel kérdést alább, és más felhasználók válaszolnak Önnek




Útmutatók légkondicionáló Beko

Beko

Beko BEPB12H Útmutató

12 Január 2025
Beko

Beko EFE6030W Útmutató

31 December 2025
Beko

Beko BK 6300 Útmutató

21 Szeptember 2024
Beko

Beko BRH 246 Útmutató

25 Augusztus 2024
Beko

Beko BPVOW 090 Útmutató

25 Augusztus 2024
Beko

Beko BRH 076 Útmutató

25 Augusztus 2024
Beko

Beko BRH 245 Útmutató

25 Augusztus 2024
Beko

Beko BRH 075 Útmutató

25 Augusztus 2024
Beko

Beko BINR 241 Útmutató

25 Augusztus 2024
Beko

Beko BINR 091 Útmutató

25 Augusztus 2024

Útmutatók légkondicionáló

Legújabb útmutatók légkondicionáló